Transcription of XRF SAMPLE CUPS SpectroCertified XRF Sample Cups …
1 Chemplex Industries, Inc. maintains a design engineering department together with a contemporary equipped machine shop facility. Chemplex products are manufactured in-house starting from the initial product conception, design, prototype, testing, and evaluation stages to finished inventoried products. In many instances, the machinery to make a product is not available necessitating the in house design and custom fabrication of the actual production equipment. The design of SAMPLE cups begins with an innovative idea for a method of containing and handling liquid and powdered SAMPLE substances for x-ray analysis.
2 Many Chemplex XRF SAMPLE Cup designs and applications are classified as innovatively unique and have been awarded intellectual property status with the USPTO. With a battery of injection molding machines and adjunct equipment in its manufacturing section, SAMPLE cups are: manufactured on a daily basis; subject to quality control at the production stage; packaged and labeled to avoid contamination; and inventoried under a protective environment to maintain their original quality and to assure prompt delivery. XRF SAMPLE cups SpectroCertified XRF SAMPLE cups SpectroCertified XRF SAMPLE Cup Quality Starts with a Special Formulated Polyethylene Typical Characteristics of SpectroCertified Chemplex XRF SAMPLE cups Trace Analyte Impurities, PPM Melting Point, oC (oF) Softening Point, oC (oF) Ca, Mg, Ti, Al, P, Zn 130 (266) 123 (253) The extraordinary attention given to a special formulated plastic and maintaining consistency of its physical and chemical properties is costlier than conventionally available plastics intended for genera purpose use.
3 Chemplex XRF SAMPLE cups are unmatched in material composition and properties for their intended XRF scientific applications. SpectroCertified and Chemplex are registered trademarks of Chemplex Industries, Inc. Made under one or more of patents; 5,630,989; 4,698,210; 238,210; 4,665,759 and pending applications HOME TECHNICAL REPRINT: Disposable SAMPLE cups for X-Ray Fluorescence Analysis SAMPLE CUP SELECTION GUIDE QUICK REFERENCE CHART FOR XRF SAMPLE cups THIN-FILM SAMPLE SUPPORTS TRANSFER PIPETTES SAMPLE CUP ACCESSORIES RoHS COMPLIANT MICROPOROUS FILM Chemplex XRF SAMPLE cups are injection molded from a proprietary high-density polyethylene specially formulated for this application.
4 The material is characterized with: Compliance with RoHS Directive Absence of whitening agents that may potentially influence x-ray data Lubricity to facilitate the smooth and firm attachment of thin-film SAMPLE support windows Physical characteristics for performance and resistance to thermal and irradiation exposure Chemical resistance from contact with incalculable SAMPLE material substances Low trace element impurities SAMPLE CUP SIZE SELECTION GUIDE HOW TO SELECT AN XRF SAMPLE CUP SIZE
5 Note: SAMPLE holder photographs are a courtesy of Bruker AXS. Chemplex INDUSTRIES, INC. 2820 SW 42nd Avenue Palm City, Fl. 34990-5573, USA Continental USA Toll Free: (800) 4-CHEMPLEX Phone: (772) 283-2700 Fax: (772) 283-2774 Email: On Line Sales: HOME QUICK REFERENCE CHART FOR XRF SAMPLE cups THIN-FILM SAMPLE SUPPORTS TRANSFER PIPETTES SAMPLE CUP ACCESSORIES MICROPOROUS FILM Selection of a SAMPLE cup begins with taking three measurements of the SAMPLE cup holding device provided with the x-ray instrumentation: 1. Inside diameter 2. Inside diameter of the aperture 3.
6 Maximum height Match up the SAMPLE cup holder measurements to the listing of XRF SAMPLE cups in Quick Reference Chart . The XRF SAMPLE cups are categorized into Series that have common sizes and features. Select the attributes and conveniences of the XRF SAMPLE Cup that is most suitable for the application. If there is still doubt about an appropriate fit, request free SAMPLE quantities. Measure Inside Diameter, A. Measure Inside Diameter of the Aperture, B. Measure Inside Height, C. XRF SAMPLE cups QUICK REFERENCE CHART for XRF SAMPLE cups XRF SAMPLE Cup Dimensions, Attributes and Instrument Compatibility XRF SAMPLE cups are available in a variety of dimensions and attributes.
7 To match a SAMPLE cup to the SAMPLE holding device (metal SAMPLE cup, rotating tray, slide platform, fixed stage, etc.) supplied with the instrumentation measure the inside diameter, height and aperture. The following generic SAMPLE cup in conjunction with the chart serves as a guide for selecting the most appropriate size. The attributes of the various types of SAMPLE cups are also indicated to better serve the application. Reference to a Series constituting specific details of the selected SAMPLE cup narrows the selection process. For more detailed information on any SAMPLE cup in a Series, simply click on the Series Number.
8 Series Cat. No. Diameter A Height B Aperture C Max. Dia. D X-Ray Equipment Compatibility SAMPLE Cup Attributes 1060 ( ) ( ) ( ) 1065 ( ) ( ) ( )Bruker, Jordan, Kevex, Metorex, Panalytical, Philips, Rigaku, Siemens, Spectrace, Spectro, Thermo 1070 ( ) ( ) ( )ARL, Asoma, Bruker, Jordan, Kevex, Metorex, Panalytical, Philips, Rigaku, Siemens, Spectrace, Thermo 1075 ( ) ( ) ( ) N/A ARL, Asoma, Bruker, Fisons, Jordan, Kevex, Metorex, Panalytical, Philips, Rigaku, Siemens, Spectrace, Thermo, 1080 ( ) ( ) ( ) ( mm) 1083 ( ) ( ) ( ) ( ) 1085 ( ) ( ) ( ) ) SpectroSulfur Analyzer SAMPLE cups (Also See 1850)
9 1000 1095 (See 2195) ( ) ( ) ( ) ( ) Rigaku, Panalytical Venus 200 TrimLess Attachment of Thin-Film SAMPLE Supports by Use of Provided Sleeves. Venting Provision and External Overflow Reservoir. 1330 1330-SE (Integrated thin-film trimmer) ( ( ( 1300 1340 ( ) ( ) ( ) N/A ARL, Asoma, Bruker, Fisons, Jordan, Kevex, Metorex, Oxfordd, Panalytical, Philips, Rigaku, Siemens, Spectrace, Spectro, Thermo Re-Closable Ventable Snap-On Cap, External Overflow Reservoir, Bead-to-Indent Snap-On Ring Geometry. HOME SAMPLE CUP SELECTION GUIDE THIN-FILM SAMPLE SUPPORTS SAMPLE CUP ACCESSORIES TRANSFER PIPETTES MICROPOROUS FILM 1430 1430-SE (Integrated thin-film trimmer) ( ) ( ) ( )Asoma, Bruker, Jordan, Fisons, Jordan, Kevex, Metorex, Panalytical, Philips, Rigaku, Siemens, Spectrace, Spectro, Thermo 1440 ( ) ( ) ( )ARL, Asoma, Bruker, Jordan, Fisons, Kevex, Metorex, Oxford, Panalytical, Philips, Rigaku, Siemens, Spectrace, Spectro, Thermo 1400 1440L ( ) ( ) ( ) N/A Jordan, Oxford, Rigaku Single Open-End.)))
10 Double Venting Provision. Micro SAMPLE Mounting and Powder Thin-Layered Sandwiching Provision. Bead-to-Indent Snap-On Ring Geometry. SE catalog numbers have integrated thin-film trimmer. 1530 1530-SE (Integrated thin-film trimmer) ( ) ( ) ( )Asoma, Bruker, Jordan, Fisons, Jordan, Kevex, Metorex, Panalytical, Philips, Rigaku, Siemens, Spectrace, Spectro, Thermo 1500 1540 ( ) ( ) ( ) N/A ARL, Asoma, Bruker, Jordan, Fisons, Jordan, Kevex, Metorex, Panalytical, Philips, Rigaku, Siemens, Spectrace, Spectro, Thermo Double Open-Ended for Top SAMPLE Loading and Affixing Microporous Film or Snap-On Cap; Bead-to-indent Snap-On Ring Geometry.