1 YELLOW JACKET Recovery Machines for every refrigerant, every size systemYELLOW JACKET Recovery Machines for every refrigerant, every size system5 RecoverX Family of Refrigerant RecoveryMachinesNEWNEW6 When you see the YELLOWJACKET name on a hose, you know you vegot the genuine item for industryproven performance. Today, you llalso find the YELLOWJACKET nameon a line of refrigerant recoverymachines for the smallest applianceto the largest system. All are backed by the experience of having more units in the fieldthan the total of many differentcompetitive units combined. Building block approach to select a system for your needsMake your selection based on system size, your budget, and performance features that buildthrough the line.
2 On this page,start with the high speed of theRecoverXL. Add automatic operation with the RecoverXLTand then subcooling with theRecoverXLS and RecoverXLSinclude a 3-Year warranty oncompressorEvery unit is full-function tested in the factory to help insure trouble-free operation. Results anda full 1-year warranty (3 year compressor warranty on RecoverXLTand RecoverXLS) are includedwith each RecoverX 1-800-769-8370for technicalsupport for as long as you own theequipment. Telephone calls typicallysolve 90% of problems withoutreturns. Technical support is alsoavailable in Europe. Replacementparts are easy to install and readilyavailable through your JACKET Refrigerant RecoveryMachines the growing line for every size systemRecoverXL REFRIGERANT Recovery Machines fast Recovery of most refrigerants including R-410 AThe YELLOWJACKETR ecoverXLMachine provides fast Recovery ofClass III, IV, and V refrigerantsincluding R-410A.
3 Features include all of the following: Durability with proven 1/2 hp oil-lessdirect drive compressor. Permanentlylubricated cylinder walls eliminate oil maintenance and compatibility problems Built-in mesh particulate filterto protect unit from dirty systems On-the-fly purge with simple turn of a knob to remove residual refrigerant and help prevent cross contamination Easy, intuitive use with single-valve set-up and no hose switching (patent pending)See page 10 for selection weight of all units balance awayfrom the side of your leg for easier carrying on a long walk to the back of a house or a long climb to a roof Federal laws prohibit venting or blowing off a chargeduring service, a Recovery unit is # Description Compressor 95740 RecoverXL 115/60 Hz 1/2 hp oil-less95753 RecoverXL 230/50 Hz (Euro plug )1/2 hp oil-lessStart with the features of the RecoverXand add fully automatic operationforevery refrigerant.
4 Single valve control for easy changeover from liquid to vapor to purge (patent pending) CPR valve regulates refrigerant to the compressor. Eliminates the need for the technician to throttle the suction valve. Protects the life of your compressor,and your investment Advanced 1/2 hp, 3425 rpm oil-less compressor with precision valves manufactured in an ISO-9001 facility Recovers refrigerant and shuts off when unit reaches 15" of vacuum. Unit will automatically restart if system pressure rises LED signals Recovery completion High efficiency fan keeps air moving across condenser for cool running even in hot weather Senses back pressure from tank and shuts off automatically at 520 psi for safety Single high pressure safety switch Reusable mesh particulate filter inserts into suction port for protection.
5 Simple cleaning eliminates replacement due to clogging Color-coded hook-ups for proper use On-the-fly purge with simple turnof a knob to remove residual refrigerant and help prevent cross contamination Designed and manufactured in USA Tested by UL to ARI 740-987 High efficiency fan keeps air moving across the condenser forcool running even in high temperatureoperating cord UNIVERSAL Recovery Machines adds fully automatic operation to the full features of RecoverXLSee refrigerant ratings chart for all machineson page UPC# Description Compressor 95760 RecoverXLT 115/60 Hz1/2 hp oil-less 95762 RecoverXLT with tank overfill switch 115/60 Hz1/2 hp oil-less 95763 RecoverXLT 230/50 Hz (Euro plug )1/2 hp oil-less95767 RecoverXLT 230/50 Hz (UK plug) 1/2 hp oil-lessR-410A ready color-coded gauges (500 low side; 800 high side) Reusable meshparticulate filterinserts into suction port forprotectionRecovery complete indicatorCircuit breaker95762 (Shown)Single valve control for easychangeover from liquid to vapor topurge (patent pending)Constant pressureregulator valve toregulate refrigerantinput and protectcompressor life.
6 Quiet running with components nested to reduce vibration and compressor is inherently quiet. Tough HDPE case dampens vibration rather than amplify it like metal High volume air flow ducted over large condenser for cool running even in high ambient temperatures Controls and gauges inset for protection and angled for easy accessand viewing High strength construction for rugged use, yet lightweight at less than 33 pounds. ( kg). Roundedcorners help protect you and your customers property from scrapes8 RecoverX REFRIGERANT Recovery Machines cost-effective for smaller systems and push/pull liquid applicationsThis economical Recovery unit buildson the performance and success of theoriginal YELLOWJACKET RecoverXRecovery machine over 50,000 features include the following: Maximum air flow and cool runningeven in high ambient temperatures.
7 High efficiency fan keeps air moving across condenser High strength HDPE case for light weight and rugged use. Rounded corners help protect you and your customers from nicks and scrapes Whisper-quiet 1/6 hp oil-filled reciprocating hermetic compressor charged with polyol ester oil. Oil drain port for easy maintenance Controls and gauges inset for protection and angled for easy access and viewing High pressure switch with automatic reset and external circuit breaker Designed and manufactured in USASee page 10 for performance andselection chart. When ambienttemperaturesgo up at a service site,refrigerant inthe Recovery tankgets hot and expandsto increase pressure, reducing Recovery speed.
8 You could either icethe tank to cool and condense the contents or just flip the subcoolingswitch on the new RecoverXLSM achine. The switch is faster andmore lowersthe temperature of refrigerant belowits dew point. In subcooling modethe RecoverXLS draws hot vaporfrom the Recovery tank and it goesback through the condenser. Thevapor is cooled and returned to thetank as a liquid to lower tank tempand pressure. With a cooler tank andlower pressure, you can fill the tankmore quickly with more refrigeranton hot days, and help maximize compressor a simple 3-hose hook-up when connecting theRecoverXLS to the system and the RecoverXLT Recovery isautomatic.
9 Simply connect the vaporout from the Recovery tank to thesubcooling port on the refrigerant will flow while thesubcooling switch is Off. Turn the suction valve to the Off position and the subcooling switch On. Vapors will be collected from the Recovery tank, circulated throughthe RecoverXLS condenser, and thenreturned to the Recovery tank ascooled liquid to lower both tank temperature and pressure. Simply flip the switch to the Off position when the tank has cooled tothe desired level and continue therecovery process as UNIVERSAL Recovery Machines addssubcoolingto the RecoverXLTUPC# Description Compressor 95700 RecoverX 115/60 Hz 1/6 hp hermeticAvailable in Spring 2007 Available in Spring 2007To 110V groundedreceptacleLiquid (open)Vapor (closed)(unless in subcool mode)ScaleLiquid serviceport (liquidrecovery only)HVAC unitor applianceVapor service port(liquid or vapor Recovery )
10 To subcool portRECOVERYTANK9R 100 SERIES REFRIGERANT Recovery Machines the speed you need for larger commercial jobsThis is the high speed system for largequantity refrigerant transfer, junkyardtransfer, supermarket rack systems, andother larger commercial jobs. Fast twin cylinder 1 hp oil-less compressor recovers direct liquid at up to 5 lbs/min., or .6 vaporper ARI 740-95 High capacity 6" muffin fan and oversized 3/8" slit fin condenser with 3-pass path for cool running in high ambient temperatures Tank overfill sensor Built-in reusable mesh particulate filter to protect from dirty systems On-the-fly purge with simple turn of a knob to remove residual refrigerant and help prevent cross contamination Designed and manufactured in USASee page 10 for performance andselection GLASSMESH PARTICULATE FILTERUse with YELLOWJACKETR ecoverX andRecoverXL Machines .