your GUIDEtoSUCCESSFUL OPERATIONof theCATGENIE 12O 2010 PetNovations, Inc., ManualupdatesTIP: Watch Video of What to Expect During Cleaningat World s Only Self-Flushing, Self-Washing Cat Box IMPORTANT SAFETY INSTRUCTIONSTo Prevent Risk of Fire, Electric Shock, or Injury to People and PREVENT FIREor shock hazard, do NOT expose theCatGenie Processing Unit to rain or sources of splashingwater. Do NOT operate the CatGenie with wet ALL INSTRUCTIONS BEFORE INSTALLINGAND USING your CatGenie . USE THECATGENIE ONLY FOR ITS INTENDED modifications or changes not explicitly described orapproved of in this manual could void your :Basic safety precautions must and shouldalways be followed to reduce the risk of personal SAFETYS hould any solid object fall on or into the Processing Unit or shouldliquid

SaniSolution Smart Cartridge Processing Unit Hopper Cover GenieEyes Cat Sensor GenieHand Bowl Brim Hopper, Impeller, Red Drain Washer Water Sensor Genie Water

Tags:

  Guide, Your, Water, Your guide

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of YOUR GUIDE - CatGenie

1 your GUIDEtoSUCCESSFUL OPERATIONof theCATGENIE 12O 2010 PetNovations, Inc., ManualupdatesTIP: Watch Video of What to Expect During Cleaningat World s Only Self-Flushing, Self-Washing Cat Box IMPORTANT SAFETY INSTRUCTIONSTo Prevent Risk of Fire, Electric Shock, or Injury to People and PREVENT FIREor shock hazard, do NOT expose theCatGenie Processing Unit to rain or sources of splashingwater. Do NOT operate the CatGenie with wet ALL INSTRUCTIONS BEFORE INSTALLINGAND USING your CatGenie . USE THECATGENIE ONLY FOR ITS INTENDED modifications or changes not explicitly described orapproved of in this manual could void your .

2 Basic safety precautions must and shouldalways be followed to reduce the risk of personal SAFETYS hould any solid object fall on or into the Processing Unit or shouldliquid penetrate the Processing Unit, unplug the CatGenie and haveit checked by qualified personnel before the CatGenie Electric Cord from the outlet beforeattempting to clear a jam or remove an object from the Hopper sprocessing area. Do NOT put fingers or hands into the Hopperopening while the CatGenie is POWER SOURCESB efore operating the CatGenie , check that your local powersupply is identical to the CatGenie operating voltage, which is120 VAC.

3 See complete specifications inGray Box on the CatGenie FROM ITS ELECTRIC OUTLET beforecleaning the Processing Unit or washing any other CatGenie :When you remove the Processing Unit from its Base,current is still going to it, so unplug the Genie Electric Cord you are not going to use the CatGenie for an extendedperiod of time, disconnect the CatGenie from the electric disconnecting the CatGenie electric power cord, pullthe PLUG. NEVER pull the cord. A damaged or defective ACpower cord should be changed at a qualified service PLACEMENTP osition the CatGenie in a place with adequate ventilation toprevent heat build-up and to prolong the life of the NOT place CatGenie near heat sources, or in a placesubject to direct sunlight, excessive dust.

4 Or mechanical NOT place anything on top of or behind the may block ventilation holes and cause NOT install or store the CatGenie where it could beexposed to rain or splashing the Simple Setup GUIDE for site selection OPERATIONB efore connecting the CatGenie to the power source, be sureto read this manual. NEVER, under any circumstances, connectthe CatGenie to a power source unless the CatGenie ProcessingUnit is properly seated and secure in its slot in the NOT operate CatGenie with wet hands. Follow allinstructions and warnings in all CatGenie CLEANINGC lean the Processing Unit and Control Panel only with a softdamp cloth slightly moistened with water .

5 NEVER immerse it inor spray it with NOT use any type of abrasive pad, scouring powderor solvent such as alcohol or benzene. See Cleaning theCatGenie on page 16 for further you have any questions or problems concerning yourCatGenie, please contact our technical support staff at:1-888-735-3927 PetNovations, Inc. cannot assume responsibility for any andall possible damage if CatGenie is inappropriately operatedor used for a purpose other than that for which it is PetNovations, Inc. reserves the right to change designand specifications without notice, we do alert our customersabout upgrades and product receive news of upgrades, improvements, andspecial offers, register your Warranty SPECIFICATIONSfor NORTH AMERICA Power Requirements:120 VAC, 60Hz (15A Fused) Power Consumption:20W (Cleaning Cycle-17 Minutes)1200W (Drying Cycle-17 Minutes) Approximate Weight:Total CatGenie : 25 lbs.

6 (Includes Processing Unit, 11 lbs. Base Unit, 14 lbs) Supplied Accessories:Utility or Laundry RoomT-Adapter, Bathroom or Powder Room T-Adapter,SaniSolution Cartridge, and Washable Program Cat Program Auto Start .. Program Child Washable SaniSolution .. CatGenie Bath & Laundry Correct Setup Spare Errors 1, 2, 3, 4 Beeps & Lights .. Errors without Machine Cleaners .. How to Clean the water Clear Technical Notice & , Money-Back SUPPORTP lease call or email Customer Support if you see visibledamage to your CatGenie or if you have cat adjustmentproblems.

7 We are happy to assist you with ANY questionor issue that you may have concerning your : 1-888-SELF-WASH 1-888-735-3927 Email: OWNER S GUIDETABLE OF CONTENTSHow do I mutewarning beeps?Press &Releasethe Start/Pause QUICK FIXMany problems are caused by & sure that your cold water supply is turned onand that the knob is turned on all the electric power. Plug in electric cord. Check thatthe Processing Unit is correctly placed in its the water Sensor. Remove the Processing out water Sensor, clean its tip, page Hopper. Unplug electric.

8 Remove Hopper obstruction. Replace cover. Plug page bent or crimped CatGenie water supplyand drain SHOOTINGSee Pages 12, 13, 14, NumberSerial Number is on the back of the Processing OF THE CatGenie 12 OSaniSolution12O CartridgeDispenses exact amountof sanitizing fluidGenie EyesSees when cat is in theBowl. Won t start Cyclefor 10 minutesControl PanelUse to programStart Cycle. Beeps& Blinks warn of errorsWashableGranulesNon-absorbent, shedliquids, Granules neverneed changingProcessing UnitIt s the CatGenie motors, solutionpump unit, electronicsGenieWaterHoseConnects to coldwater supply line inbath or laundryGenie Electric CordPlugs into AC DrainHoseDrains into toilet or wastepipe in laundry or utility roomWater SpoutFresh water flowsinto BowlDryer SpoutHot air blows outand into BowlDrainHookAttaches to GenieDrainHose for useover toilet rimGenie HandMulti-functional tool scoopssolids.

9 Scrubs and scoursGranules, itself, and insideBowl. Sifts through Granulesfor complete dryingHopperChamber whereImpellermacerates wasteBowlWhere cat feels at home inthe cat-comfy GranulesBrimEncircles the Bowl;attaches to BaseBaseVery bottom ofCatGenieHopper CoverStore GenieHand,Hides HopperImpellerWaterSensorInsideHopperRed DrainWasherHairCutterRingSaniSolutionSma rt CartridgeProcessing UnitHopper CoverGenieEyesCat SensorGenieHandBowlBrimHopper, Impeller,Red Drain WasherWater SensorGenie water Supply LineGenie Electric CordGenie DrainHoseIS THE SANISOLUTION CLEANER SAFE FOR MY CAT?

10 Yes, SaniSolution is safe for cats. Its ingredients are like those used byveterinarians to disinfect their operating areas. Liquid in the Cartridge ishighly concentrated. In this form, it is safe as long as it is in the LONG DOES THE SANISOLUTION LAST?On Cat Activation,one SaniSolution Cartridge is good for 240 Auto Set, one is good for 120 Cycles. ALWAYS keep extra Cartridgeson hand. The price of SaniSolution equals the yearly cost of cat litter,yet it s just a fraction of the size and weight of THE SANISOLUTION DISSOLVE OR LIQUEFY SOLIDS?