Example: marketing

z.one Ultrasound System pro Specification Sheet - Mindray

Ultrasound System Specification SheetK90139C | August 2014 | Ultrasound System SpecificationsiTable of ContentsSpecificationsZONE Sonography Technology (ZST) ..2 Architecture ..2 Applications ..2 Site Requirements ..2 System Warranty ..2 Dimensions ..3 System Design ..3 Display ..3 User Interface ..4 TransducersC4-1 Curved Array..5C6-2 Curved Array..5C9-3 Curved Array..6C10-3 Curved Array ..6E9-4 Endocavity ..7L8-3 Linear Array ..7L10-5 Linear Array ..8L14-5sp (Special Procedures) Linear Array ..8L14-5w (Wide Field-of-View) Linear Array ..9P4-1c Phased Array..9A2CW ..10A5CW ..10P8-3 TEE Phased Array ..10 Transducer Performance Data ..11 Imaging ModesB-Mode ..12M-Mode ..12 Color and Power Doppler ..13 Pulsed Wave Doppler ..13 Continuous Wave Doppler ..14 Dual Imaging ..14 Simultaneous Dual Imaging ..14 Imaging Mode Combinations ..14 Imaging Formats ..15 Contrast Enhanced Ultrasound ..15 Auto-Opt with ZST ..15 Acoustic Zoom ..15 Display Zoom.

Specifications K90139C | August 2014 | z.one pro 2 Ultrasound System Specifications ZONE Sonography™ Technology (ZST) ZONE Sonography Technology is an entirely new approach to ultrasound image acquisition and processing.

Tags:

  System, Ultrasound, Ultrasound system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of z.one Ultrasound System pro Specification Sheet - Mindray

1 Ultrasound System Specification SheetK90139C | August 2014 | Ultrasound System SpecificationsiTable of ContentsSpecificationsZONE Sonography Technology (ZST) ..2 Architecture ..2 Applications ..2 Site Requirements ..2 System Warranty ..2 Dimensions ..3 System Design ..3 Display ..3 User Interface ..4 TransducersC4-1 Curved Array..5C6-2 Curved Array..5C9-3 Curved Array..6C10-3 Curved Array ..6E9-4 Endocavity ..7L8-3 Linear Array ..7L10-5 Linear Array ..8L14-5sp (Special Procedures) Linear Array ..8L14-5w (Wide Field-of-View) Linear Array ..9P4-1c Phased Array..9A2CW ..10A5CW ..10P8-3 TEE Phased Array ..10 Transducer Performance Data ..11 Imaging ModesB-Mode ..12M-Mode ..12 Color and Power Doppler ..13 Pulsed Wave Doppler ..13 Continuous Wave Doppler ..14 Dual Imaging ..14 Simultaneous Dual Imaging ..14 Imaging Mode Combinations ..14 Imaging Formats ..15 Contrast Enhanced Ultrasound ..15 Auto-Opt with ZST ..15 Acoustic Zoom ..15 Display Zoom.

2 15 SpecificationsImage Display ..16 Cine Memory ..16 Exam Management & Presets ..17 Image Management ..17 Connectivity ..18 Optional Peripherals ..18 User Editable Worksheets Option ..18 Measurements & AnalysisAuto-Dop Trace (Automatic Doppler Measurements) ..19 General Capabilities ..19 Generic B-Mode Measurements / Calculations ..19 Generic M-Mode Measurements/Calculations ..19 Generic PW Measurements/Calculations ..19OB Measurements/Calculations ..20 Abdominal Measurements/Calculations ..21 Pediatric Hip Measurement ..22B-Mode (Fetal Heart) ..22PW-Doppler (Fetal Heart) ..22M-Mode (Fetal Heart) ..23 GYN Measurements / Calculations ..23 Vascular Measurements / Calculations ..23 Carotid ..23 Upper Extremity Arterial Calc (Right/Left)Stenosis, Diameter, PW Doppler, Report Page ..23 Lower Extremity Arterial Calc (Right/Left)Stenosis, Diameter, PW Doppler, Report Page ..24 Lower Extremity Venous MeasurementsDiameter, Checklists, Report Page.

3 24 Upper Extremity Venous MeasurementsDiameter, Checklists, Report Page ..25 SpecificationsAnnotation Package ..26 Safety and Regulatory ..26 SpecificationsK90139C | August 2014 | Ultrasound System Specifications2 ZONE Sonography Technology (ZST)ZONE Sonography Technology is an entirely new approach to Ultrasound image acquisition and processing. Conventional systems acquire acoustic data line-by-line and focus it with a beamformer using only a small fraction of the actual information contained in the echo data set. ZONE Sonography Technology has the ability to utilize all of the information contained in the returning echo data set and as such can cover the field of view in much fewer transmit / receive cycles. While it might be intuitive that simultaneously collecting data from these larger regions would be more efficient, it is understandably less intuitive that fewer acquisitions could result in improved image quality. ZONE Sonography Technology enables this performance advantage by retrospectively analyzing these complete echo data sets to synthesize a continuous transmit focus at every image ZONE Sonography Technology, some of the image quality improvements include:1.

4 Focused image across the full field of viewa. Dynamic transmit & receive focus (Every pixel in the frame is in focus)i. No need for transmit focal zone control and resultant frame rate tradeoffsb. Enhanced image resolution, uniformity, contrast, and penetration2. Faster acoustic acquisitiona. Temporal accuracy (reduced motion blur)b. Acoustic time available to interleave modes without performance compromise3. Patient specific imaginga. Compensating for physiological sound speed variations in patients4. Novel Techniquesa. Compound contrast imagingb. Flexible image formats (phased array imaging on curved transducers, linear on curved, etc.)Architecturen > 100,000 dynamic channels per framen Frame Rate: > 60 frames per secondn Total System Dynamic Range 250 dBn Boot-up time: < 30 secondsLanguages Supported: n English n German n Swedish n French n Italian n Russiann SpanishApplicationsn Abdominaln Abdominal Vascular n Anesthesian Breastn Contrast Enhanced Ultrasound * (CEUS)n Echocardiography *n TEEn Emergency Medicine (FAST Exam, Central Lines, Peripheral Venous Access)n Endocavity (Endovaginal, Endorectal)n Prostaten Gynecologic (including Endovaginal)n Intraoperative (Vascular/Superficial)n Interventional (Guided Needle Procedures)n Musculoskeletal (MSK)n Neonatal/Pediatric Abdomen, Echocardiography, Head, Hip n Obstetrics (all trimesters)n Ocular n Superficial Partsn Testicular/Scrotumn Thyroidn Transcranial Imaging with Dopplern Vascular (Extracranial, Peripheral, Deep)Site Requirementsn 100-240 VAC, 50-60 Hzn 180W (616 BTU/hr) with no peripheralsn 470W (1608 BTU/hr)

5 With peripheralsn Ambient air temperature of 0 35 Celsiusn Ambient relative humidity of up to 80%, non-condensingn Ingress Protection Rating: IP20 System Warrantyn 1st year warranty includes parts for normal wear and failure, and labor n 5 year warranty includes parts for normal wear and failure* Feature is only available for sale in specific countries. Please contact your local representative for | August 2014 | Ultrasound System Specifications3 SpecificationsDimensionsn Height: Max operational: 157 cm (62 in) Min operational: 128 cm ( in) Display lowered for transport: 104 cm (41 in)n Width: 51 cm ( in)n Depth: 72 cm ( )n Weight: 66kg or 147lbsSystem Designn Small footprint and light-weight System design for effortless maneuverability and maximum versatility in tight or crowded spaces n Nitrogen gas shock for vertical height adjustment up to 15 cm (6 in) of the user interface console for ergonomic customizationn 13 cm (5 in) diameter wheels with dual shock resistant front and back wheelsn Front wheels are switchable brake, direction lock, and both front and back wheels are full Solid State 120GB (or greater) Hard Drive for enhanced image storage capabilitiesn Import/export of exams to, optional, DVD+R or CD-R media or Flash Driven Monitor mounted stereo speakers n Transducer storage up to 4 transducers n Three (3) active transducer portsn Convenient cable managementn (2) Gel holdersn Power cord wrap featuresn Integrated front handle for transport and position n Saddle bag storage bins Displayn 17 (43 cm)

6 High resolution color LCD n 1280x1024 pixel resolutionn mm pixel pitchn 256 (8 bit) discrete RGB levelsn Viewing angle (H/V): 178 degrees typicaln Minimum 550:1 contrastn Backlit (190 cd/m2) and low glare for bright environmentsn Dynamic feedback sensor for controlling backlight stability and enabling fast warm-upn Height adjustment via console adjustmentn +/- 75 horizontal rotationn 20 backward tiltn Full 90 forward tilt into secure transport positionn Integrated Brightness and Contrast controls with on-screen feedbackSpecificationsK90139C | August 2014 | Ultrasound System Specifications4 User Interfacen Streamlined keyboard layout for best user ergonomicsn Optional special procedures UI with fewer hard keys *n Home base design for easy access to major modesn Full size, backlit QWERTY keyboard with non-English accents and charactersn OLEDs display customized controls for selected imaging modes provides for a less cluttered keyboardn Context-sensitive backlit keysn (8) DGC slide potentiometers with 45 mm travel and +/- 20dB Gainn (4)

7 User-programmable Function keys Unassigned Full Image Display Archive Hide Pt. Bar Auto trace Image Width Body Patterns Lt/Rt Invert B-Mode Microphone B-Steer Power Dop Bx Guide Presets Compounding Print Contrast Protocol Cursor Record Custom Preset Remove Data Fields d-PDI Review Display Format Shutdown Dual Stpwatch Phse/Reset ECG Stpwatch Start/Stop Elastography Simul Dual Ext. Sync Transducer Freeze Up/Down Invertn (3) User-programmable Mode keys Unassigned d-PDI 3D Elastography Auto trace Presets Aux CW Power Doppler Contrast TDI CW Transducern Context-sensitive onscreen menun 38mm diameter trackball* Option is only available for sale in specific countries. Please contact your local representative for | August 2014 | Ultrasound System Specifications5 TransducersNew transducer technology, wide bandwidth imaging, and multiple frequency imaging with an expanded range of frequencies including Compound Harmonics.

8 These features provide:n Increased sensitivity and resolution n More clinical information and expanded applicationsThe transducers are lightweight and ergonomically designed to offer easier imaging access, increased operator comfort, and greater overall clinical impact across all patient Curved Phased Array TransducerPrimary Applications: Abdominal, Abdominal Vascular, Obstetrics, Fetal Heart, Gynecologic, CEUS*, Needle Guided ProceduresSecondary Applications: CardiacBandwidth: 4-1 MHzNumber of Elements: 64 Physical footprint: of Curvature: 34mmField of View (Adjustable): 80 degreesBiopsy Guide: Optional longitudinal typeDepth: 30cmCable Length: Approx. 2 metersWeight (excl. cable and connector): 91 gramsIngress Protection Rating: IPX 712 Frequencies:2D and M-Mode: 3 MHz; MHzTissue Harmonic: MHz; MHzCompound Harmonic: 4 MHzColor / Power Doppler: MHz; MHzPW Doppler: MHz; MHzCW Doppler: MHz; MHzTissue Doppler: MHz: ZONARE PN: Z119-30 ZONARE PN: Z111-30C6-2 Curved Array TransducerPrimary Applications: Abdominal, Abdominal Vascular, Obstetrics, Fetal Heart, Gynecologic, Needle Guided ProceduresSecondary Applications: Peripheral VascularBandwidth: 6-2 MHzNumber of Elements: 128 Physical footprint: 66x18mmRadius of Curvature: 50mmField of View (Adjustable): 65 degreesBiopsy Guide: Optional longitudinal typeDepth: 24cmCable Length: Approx.

9 2 metersWeight (excl. cable and connector): 136 gramsIngress Protection Rating: IPX 711 Frequencies:2D and M-Mode: MHz; MHzTissue Harmonic: MHz; MHz; MHzCompound Harmonic: ; MHzColor / Power Doppler: MHz; MHzPW Doppler: MHz; MHz* Feature is only available for sale in specific countries. Please contact your local representative for | August 2014 | Ultrasound System Specifications6 TransducersC9-3 Curved Array TransducerPrimary Applications: Abdominal, Abdominal Vascular, OB, Pediatric/Small Adult AbdomenSecondary Applications: Peripheral VascularBandwidth: 9-3 MHzNumber of Elements: 128 Physical footprint: 46x14mmRadius of Curvature: 33mmField of View (Adjustable): 67 degreesBiopsy Guide: Optional longitudinal typeDepth: 18cmCable Length: Approx. 2 metersWeight (excl. cable and connector): 91 gramsIngress Protection Rating: IPX 713 Frequencies:2D and M-Mode: MHz; MHz; MHzTissue Harmonic: MHz; MHz; MHzCompound Harmonic: MHz; MHzCompound: MHzColor / Power Doppler: MHz; MHzPW Doppler: MHz; MHzZONARE PN: Z109-30C10-3 Curved Phased Array TransducerPrimary Applications: Neonatal Heart, Neonatal Head, Neonatal Abdominal, Pediatric Echo, Pediatric Abdominal, OcularSecondary Applications: Peripheral VascularBandwidth: 10-3 MHzNumber of Elements: 64 Physical footprint: ~16 mmRadius of Curvature: 16 mmField of View: 80 degreesBiopsy Guide: None availableVirtual Apex Array: N/ADepth: 14 cmCable Length: Approx.

10 2 metersWeight (excl. cable and connector): 45 gramsIngress Protection Rating: IPX 718 Frequencies:2D and M-Mode: MHz; MHz; MHzTissue Harmonic: MHz; MHzCompound Harmonic: MHz; MHzColor / Power Doppler: MHz; MHz; MHz; MHzPW Doppler: MHz; MHz; Doppler: MHz; MHz; Doppler: MHzZONARE PN: Z124-30K90139C | August 2014 | Ultrasound System Specifications7 TransducersE9-4 Endocavity TransducerPrimary Applications: Endovaginal including First Trimester Obstetrics, Gyn (uterus, ovaries)Secondary Applications: Endorectal including Prostate, Rectal Wall Needle Guided ProceduresBandwidth: 9-4 MHzNumber of Elements: 128 Physical footprint: 23x20mmRadius of Curvature: 12mmField of View: 135 degreesBiopsy Guide: 1. Optional disposable 2. Optional re-useableVirtual Apex Array: N/ADepth: 14cmCable Length: Approx. 2 metersWeight (excl. cable and connector): 159 gramsIngress Protection Rating: IPX 79 Frequencies:2D and M-Mode: MHz; MHz; MHzTissue Harmonic: MHz; MHzCompound Harmonic: MHzCompound: MHzColor Doppler: MHzPW Doppler: MHzZONARE PN: Z103-30 ZONARE PN: Z106-30L8-3 Linear Array TransducerPrimary Applications: Peripheral Vascular, Needle Guided ProceduresSecondary Applications: Pediatric Hips, Technically Difficult Small PartsBandwidth: 8-3 MHzNumber of Elements: 128 Physical footprint: 48x11mmField of View (Adjustable): 38mmBiopsy Guide: Optional transverse typeVirtual Apex Array: Wider Field of ViewDepth: 10cmCable Length: Approx.