Example: bachelor of science

ZYTEL 70G33HS1L NC010 - txfbest.com

Product Information ZYTEL nylon resin ZYTEL 70G33HS1L NC01033% Glass Reinforced Nylon ResinZytel 70G33HS1L NC010 is a heat stabilized 33% glass reinforced nylon 66 resin with excellent strength, stiffness, creep resistance and fatigue endurance. Property characteristics remain at high levels over a wide range of temperatures and MethodUnitsValueDAM50%RHMechanical Tensile StrengthASTM D 638 MPa (kpsi) -40C (-40F)214 ( )207 ( ) 23C (73F)186 ( )124 ( ) 77C (170F)110 ( )86 ( ) Stress at BreakISO 527-1/-2 MPa (kpsi)193 ( )126 ( ) Elongation at BreakASTM D 638%34 Strain at BreakISO 527-1/-2% Tensile ModulusISO 527-1/-2 MPa (kpsi)10500 (1520)7000 (1015) Shear StrengthASTM D 732 MPa (kpsi)86 ( ) Flexural ModulusASTM D 790 MPa (kpsi)8965 (1300)6205 (900) Flexural ModulusISO 178 MPa (kpsi)9100 (1320)6205 (900) Flexural StrengthASTM D 790 MPa (kpsi)262 ( )

Product Information Zytel® 70G33HS1L NC010 Property Test Method Units Value DAM 50%RH Mechanical Unnotched Charpy Impact ISO …

Tags:

  Zytel, Nc010, Zytel 70g33hs1l nc010, 70g33hs1l, 174 70g33hs1l nc010

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ZYTEL 70G33HS1L NC010 - txfbest.com

1 Product Information ZYTEL nylon resin ZYTEL 70G33HS1L NC01033% Glass Reinforced Nylon ResinZytel 70G33HS1L NC010 is a heat stabilized 33% glass reinforced nylon 66 resin with excellent strength, stiffness, creep resistance and fatigue endurance. Property characteristics remain at high levels over a wide range of temperatures and MethodUnitsValueDAM50%RHMechanical Tensile StrengthASTM D 638 MPa (kpsi) -40C (-40F)214 ( )207 ( ) 23C (73F)186 ( )124 ( ) 77C (170F)110 ( )86 ( ) Stress at BreakISO 527-1/-2 MPa (kpsi)193 ( )126 ( ) Elongation at BreakASTM D 638%34 Strain at BreakISO 527-1/-2% Tensile ModulusISO 527-1/-2 MPa (kpsi)10500 (1520)7000 (1015) Shear StrengthASTM D 732 MPa (kpsi)86 ( ) Flexural ModulusASTM D 790 MPa (kpsi)8965 (1300)6205 (900) Flexural ModulusISO 178 MPa (kpsi)9100 (1320)6205 (900) Flexural StrengthASTM D 790 MPa (kpsi)262 ( )

2 Deformation Under LoadASTM D 621% 50C (122F), (2000psi) Izod ImpactASTM D 256J/m (ft lb/in)117 ( )133 ( ) Notched Izod ImpactISO 180/1 AkJ/m2 -40C (-40F)910 -30C (-22F)1010 23C (73F)1115 Unnotched Izod ImpactISO 180/1 UkJ/m2 -30C (-22F)8570 23C (73F)9590 Unnotched ImpactASTM D 4812J/m (ft lb/in)1330 (25)1490 (28) Notched Charpy ImpactISO 179/1eAkJ/m2 -40C (-40F)910 -30C (-22F)910 23C (73F)1116 Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, properties measured at 23 C (73 F) unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.

3 This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The dataprovided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information.

4 Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantationin the human body. For other medical applications see "DuPont Medical Caution Statement", H-51459 or with DuPont Engineering Polymers - InformationZytel 70G33HS1L NC010 PropertyTest MethodUnitsValueDAM50%RHMechanical Unnotched Charpy ImpactISO 179/1eUkJ/m2 -30C (-22F)7070 23C (73F)82100 Thermal Heat Deflection TemperatureASTM D 648 C ( F) (66psi)260 (500) (264psi)249 (480) Deflection TemperatureISO 75-1/-2 C ( F) (502) (480) CLTE, ParallelASTM E 831E-4/C (E-4/F) -40 - 23C (-40 - 73F) ( ) 23 - 55C (73 - 130F) ( ) 55 - 160C (130 - 320F) ( ) CLTE, NormalASTM E 831E-4/C (E-4/F) -40 - 23C (-40 - 73F) ( )

5 23 - 55C (73 - 130F) ( ) 55 - 160C (130 - 320F) ( ) Melting PointASTM D 3418 C ( F)262 (504) Melting TemperatureISO 3146C C ( F)263 (505)Electrical Relative PermittivityIEC 60250 1E2 1E6 Volume ResistivityASTM D 257ohm cm1 E15 Volume ResistivityIEC 60093ohm cm1E 16 Dielectric Strength, Short TimeASTM D 149kV/mm (V/mil) (530) Dielectric Strength, Step by StepASTM D 149kV/mm (V/mil) (440) Dielectric ConstantASTM D 150 1E3 1E6 Dissipation FactorASTM D 150 1E3 Dissipation FactorIEC 60250E-4 1E2 Hz100 1E6 Hz150 Electric StrengthIEC 60243-1kV/mm (V/mil) (685) Arc ResistanceASTM D 495s135 CTIUL 746AV>600 Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, properties measured at 23 C (73 F) unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.

6 This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The dataprovided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information.

7 Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantationin the human body. For other medical applications see "DuPont Medical Caution Statement", H-51459 or with DuPont Engineering Polymers - InformationZytel 70G33HS1L NC010 PropertyTest MethodUnitsValueDAM50%RHFlammability Flammability ClassificationUL94 Limited Oxygen IndexISO 4589%24 High Voltage Arc Tracking RateUL 746 Amm/min (in/min) ( ) Hot Wire IgnitionUL 746As9 Temperature Index RTI, ElectricalUL 746B C RTI, Mechanical with ImpactUL 746B C RTI, Mechanical without ImpactUL 746B C Specific GravityASTM D DensityISO 1183kg/m3 (g/cm3)1390 ( )

8 Hardness, RockwellASTM D 785 Scale M101 Taber AbrasionASTM D 1044mg CS-17 Wheel, 1kg, 1000 cycles14 Humidity AbsorptionISO 62, Similar to% Equilibrium 50%RH, Water AbsorptionASTM D 570% Immersion DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, properties measured at 23 C (73 F) unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise.

9 The dataprovided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantationin the human body.

10 For other medical applications see "DuPont Medical Caution Statement", H-51459 or with DuPont Engineering Polymers - InformationZytel 70G33HS1L NC010 PropertyTest MethodUnitsValueDAM50%RHOther Water AbsorptionISO 62, Similar to% Immersion 24h, Saturation, immersed, Mold Shrinkage% Flow, ( ) Molding ShrinkageISO 294-4% Normal, Parallel, Melt Temperature Range C ( F)290-305 (550-580) Mold Temperature Range C ( F)65-120 (150-250) Processing Moisture Content%< DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, properties measured at 23 C (73 F) unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.