Electrostatic Discharge Human Body Model
Found 9 free book(s)TXS0108E 8-Bit Bi-directional, Level-Shifting, Voltage ...
www.ti.comElectrostatic discharge Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000 V Charged-device model (CDM), per JEDEC specification JESD22-C101(2) ±1000 Machine model (MM) ±150 IEC 61000-4-2 ESD (B Port) Contact Discharge ±8000 IEC 61000-4-2 ESD (B Port) Air-Gap Discharge ±6000
Simulating Electrostatic Discharge - JDS
jds.elfak.ni.ac.rsmost widely used: human body model (HBM), machine model (MM) and charged device model (CDM). 2A. Human Body Model (HBM) This model corresponds to the discharge of a charged human being into the IC. The capacitance of the average human body (to ground) is 100pF. The average skin resistance is 1.5kOhm. The body capacitance is charged to
TXB0104 4-Bit Bidirectional Voltage-Level Translator ...
www.ti.comElectrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) A port ±2.5 kV Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) B port ±15 Charged-device model (CDM), per JEDEC specification JESD22-C101(2) A port ±1.5 Charged-device model (CDM), per JEDEC specification JESD22-C101(2) B port ±1.5
PESD1CAN CAN bus ESD protection diode - Nexperia
assets.nexperia.comVESD electrostatic discharge voltage IEC 61000-4-2 (contact discharge) [1][2]-23kV MIL-STD-883 (human body model)-10kV Table 7. ESD standards compliance Standard Conditions Per diode IEC 61000-4-2; level 4 (ESD) > 15 kV (air); > 8 kV (contact) MIL-STD-883; class 3 (human body model) > 4 kV Fig 1. 8/20 µs pulse waveform according to IEC 61000-4 ...
User Guide of ANSI/ESDA/JEDEC JS-001 Human Body Model ...
www.jedec.orgHuman Body Model Testing of Integrated Circuits Authors: Joint HBM Working Group ESD Association and JEDEC Solid State Technology Association Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 JEDEC Solid State Technology Association 3103 North 10th Street Arlington, VA 22201
TJA1040 High speed CAN transceiver - NXP
www.nxp.comVesd electrostatic discharge voltage Human Body Model (HBM) pins CANH, CANL and SPLIT −6+6 kV all other pins −4+4 kV tPD(TXD-RXD) propagation delay TXD to RXD VSTB = 0 V 40 255 ns Tvj virtual junction temperature −40 +150 °C TYPE NUMBER PACKAGE NAME DESCRIPTION VERSION TJA1040T SO8 plastic small outline package; 8 leads; body width …
TJA1145 - NXP
www.nxp.com8 kV ElectroStatic Discharge (ESD) protection, according to the Human Body Model (HBM) on the CAN bus pins 6 kV ESD protection, according to IEC 6 1000-4-2 on pins BAT and WAKE and on the CAN bus pins CAN bus pins short-circuit proof to 58 V Battery and CAN bus pins protected against transients according to ISO 7637-3, test
The Prevention and Control of Electrostatic Discharge (ESD ...
www.minicircuits.comWhile this sudden discharge of static electricity does not result in any harm to the human body, it can be very damaging to electronic devices which are sensitive to electrostatic discharge (ESD). It is possible for electronic devices to be damaged by ESD that is imperceptible to the human body. This document is
Basics of Electrostatic Discharge Protection
aml.ece.iisc.ac.inElectrostatic Discharge (ESD) R DUT C SUB R SUB PAD Discharge Path o Charge can be stored or accumulated across physical bodied (if isolated from ground) o It can be a human body, a machine or the electronic equipment (e.g. IC) itself (In general) ESD is the transfer of electrostatic charge between