IEEE Recommended Practice for Testing Insulation ...
1 of 26 IEEE Std P43-2000 (Revision of IEEE Std 43-2000) IEEE Recommended Practice for Testing Insulation Resistance of rotating Machinery May 2008 Draft Sponsor Electric Machinery Committee of the IEEE Power Engineering Society Reaffirmed 2006 March 2000 IEEE-SA Standards Board Abstract: This document describes the Recommended procedure for measuring Insulation resistance of armature and field windings in rotating machines rated 1 hp, 750 W or greater. It applies to synchronous machines, induction machines, dc machines, and synchronous condensers.
— Determine if the electrical insulation of a rotating machine is suitable for high-potential testing This recommended practice is intended to satisfy the following objectives: a) Promote consistency for insulation test procedures and interpretations
Download IEEE Recommended Practice for Testing Insulation ...
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Related search queries
Insulation, Rotating, Electrical, Electrical insulation, Electrical Insulation Material for High Speed/Voltage Rotating Machines, For rotating, Rotating machine insulation materials and, Rotating electrical, Insulation resistance testing, Partial discharge, Winding insulation and maintenance, Inspection and test procedures for Rotating