Search results with tag "Fastened"
DUPONT TYVEK MECHANICALLY FASTENED AIR …
www.dupont.comdupont™ tyvek® mechanically fastened air and water barrier installation guidelines for buildings greater than 4 stories and high performance installations of any height ...
DuPont Tyvek Mechanically-Fastened Water-Resistive and …
www.dupont.comMechanically-Fastened Water-Resistive and Air Barriers (Tyvek® WRBs) Product Dimensions Area DuPont™ Tyvek ® CommercialWrap® 5 ft x 200 ft 10 ft x 125 ft 1,000 sq ft 1,250 sq ft DuPont™ Tyvek ® CommercialWrap® D 5 ft x 200 ft 10 ft x 125 ft 1,000 sq ft 1,250 sq ft Self-Adhered Flashing Products Product Width
THROUGH-FASTENED ROOF/WALL PANEL SYSTEMS TABLE …
www.nucorbuildingsystems.comLAST REVISION DATE: 03/11/15 BY: AAJ CHK: MDK DETAIL NAME IF APPLICABLE SH0020PE.DWG 6.0.3 NUCOR CLASSIC ROOF™ SYSTEM The Nucor Classic Roof™ through-fastened roof system panel is available as a
Gluedown Installation Guidelines
www.karndean.comMechanically remove all paint back to the original base, prime and apply a compatible smoothing compound to a minimum of 1/8” (3 mm). 2. Wood Subfloors Standard Floorboards/Tongue and Groove Floorboards should be well secured, loose boards firmly fastened, and worn/broken boards replaced. Install a
CertainTeed Low-Slope Roof Systems FLINTLASTIC® SA
www.certainteed.comsheet (mechanically fastened); PlyBase or MidPly may be used as a base ply (fully adhered, watertight). NOTE: PlyBase or MidPly may also be used as interply layers in three-ply systems, see Application of Interply (Optional). Mechanically Attached Base Beginning at the low point of the roof, mechanically fasten Flintlastic SA NailBase
Metal Sales Product Catalog
www.metalsales.us.comCONCEALED FASTENED PANELS ... Pittsburgh double flat locking mechanically seamed side lap Concealed clip designed for thermal movement Accommodates 1/2" to 6" blanket insulation Applies over open framing or solid substrate Finishes: PVDF and Acrylic Coated Galvalume ...
DUPONT TYVEK COMMERCIALWRAP AND …
www.hllmark.comsystems that require mechanically fastened and fluid applied air and water barriers. DESCRIPTION Engineered to provide excellent performance as an air and water barrier, Tyvek® CommercialWrap® delivers the added strength and durability needed in commercial construction. As a part of DuPont™ Tyvek® Commercial Air and Water Barrier Systems,
DensDeck Roof Board - Johns Manville
www.jm.comMechanically Fastened Urethane Adhesive Hot Asphalt Cold Applied Refer to the Application Guides and Detail Drawings for instructions. Packaging and Dimensions Size 4' x 8' (1.22 m x 2.44 m) Thickness, nom ¼" (6.4 mm) ½" (12.7 mm) 5 ...
ROOFING SYSTEM APPROVAL - Miami-Dade County
www.miamidade.govSystem Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied
DuPont Tyvek Water-Resistive and Air Barriers Residing ...
www.dupont.comThe best time to install DuPont™ Tyvek ® Water-Resistive Barriers is: • AFTER the roof sheathing is installed ... water intrusion at the sill or threshold and follow the DuPont™ Tyvek ® Mechanically Fastened Air and Water Barrier Installation Guidelines For Buildings Greater Than
Firestone Polyiso Insulation
www.firestonebpco.comcan be attached with hot asphalt or low rise foam adhesive to various substrates, or mechanically fastened with Firestone fasteners and plates. PhysiCal PRoPERtiEs PRoPERty tEst MEthoD tyPiCal valuE density ASTM D 1622 2 pcf compressive strength* ASTM D 1621 20 psi dimensional stability ASTM D 2126 2% Max Moisture Vapor t ransmission ASTM E 96 ...
RetroPlus Roof Board - Johns Manville
www.jm.comMechanically Fastened Urethane Adhesive Hot Asphalt Cold Applied Refer to the Application Guides and Detail Drawings for instructions. Packaging and Dimensions Sizes 4' x 4' (1.22 m x 1.22 m) 4' x 8' (1.22 m x 2.44 m) Thickness, nom ½" (1.27 cm) Board Weight, nom 9.9 lb (4.54 kg) 19.8 lb (9.07 kg) Coverage/Pallet 15.4 squares (143 m 2) 30.8 ...
Common Supply Lists for Early Education through …
www.kusd.edu: clean, lace tied or Velcro fastened gym shoes only. No zipper, slip-on or any other fasteners will be allowed. No platform, elevated soles, …
Corrugated Polycarbonate Installation Instructions ...
igcusa.comFasteningFasteningastening Depending on wind exposure, Corrugated polycar-bonate should be fastened to the greenhouse sub-structure at …
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP …
www.ecodes.biz1504.3.2 Metal panel roof systems. Metal panel roof sys-tems through fastened or standing seam shall be tested in accordance with UL 580 or ASTM E 1592 or TAS 125.
Similar queries
Fastened, DuPont Tyvek Mechanically-Fastened Water-Resistive and, Mechanically-Fastened Water-Resistive and, DuPont, THROUGH-FASTENED ROOF/WALL PANEL SYSTEMS, SYSTEM, System panel, Mechanically, CertainTeed, Mechanically Fastened, DUPONT TYVEK, Water, Tyvek, APPROVAL, Miami-Dade County, DuPont Tyvek Water, Resistive, Lists for Early Education through, ROOF, Panel roof, Panel roof sys-tems through fastened