Transcription of 9100 - Lead in Surface Wipe Samples
{{id}} {{{paragraph}}}
NIOSH Manual of Analytical Methods (NMAM), Fourth EditionLEAD in Surface wipe Samples9100Pb MW: CAS: 7439-92-1 RTECS: OF752000 METHOD: 9100, Issue 2 EVALUATION: NOT APPLICABLEI ssue 1: 15 August 1994 Issue 2: 15 May 1996 PURPOSE: Determination of Surface contamination by lead and its OFDETECTION: 2 g Pb per sample ( g/cm for 100-cm area) by flame AAS [1] or ICP [2]; g Pb per sample ( g/cm for 100-cm area) by graphite furnace AAS [3,4].FIELD EQUIPMENT:1. Resealable hard-walled sample containers, , 50-mL plastic centrifuge tubes [5].
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition LEAD in Surface Wipe Samples: METHOD 9100, Issue 2, dated 15 May 1996 - Page 2 of 2 Include appropriate media and reagent blanks.
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
7000B: Flame Atomic Absorption, 7000B FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY, PREPARATION FOR FLAME ATOMIC, Flame atomic absorption spectroscopy, Flame atomic, LEAD ATOMIC ABSORPTION,, LEAD ATOMIC ABSORPTION, DIRECT ASPIRATION, LEAD by Flame AAS 7082, LEAD by Flame AAS, Atomic, Atomic absorption spectrometry, Atomic absorption spectrometry Atomic absorption spectrometry, Flame Photometer, Atomic Emission Spectroscopy