{{id}} {{{paragraph}}}
NIOSH Manual of Analytical Methods (NMAM), Fourth EditionLEAD in Surface wipe Samples9100Pb MW: CAS: 7439-92-1 RTECS: OF752000 METHOD: 9100, Issue 2 EVALUATION: NOT APPLICABLEI ssue 1: 15 August 1994 Issue 2: 15 May 1996 PURPOSE: Determination of Surface contamination by lead and its OFDETECTION: 2 g Pb per sample ( g/cm for 100-cm area) by flame AAS [1] or ICP [2]; g Pb per sample ( g/cm for 100-cm area) by graphite furnace AAS [3,4].FIELD EQUIPMENT:1. Resealable hard-walled sample containers, , 50-mL plastic centrifuge tubes [5].2. Wipes: Disposable towellettes moistened with a wetting 1: Wipes selected for use should contain insignificant (<5 _g Pb) background lead levels[4,5].
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition LEAD in Surface Wipe Samples: METHOD 9100, Issue 2, dated 15 May 1996 - Page 2 of 2 Include appropriate media and reagent blanks.
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
SAMPLE PREPARATION FOR FLAME ATOMIC, SAMPLE PREPARATION, Atomic absorption spectrometry, Sample preparation Sample preparation, CARBOXYMETHYL CELLULOSE, Sample, Flame, LEAD ATOMIC ABSORPTION,, LEAD ATOMIC ABSORPTION, DIRECT ASPIRATION, LEAD by Flame AAS 7082, LEAD by Flame AAS, Application note, Flame Photometer, GUIDE TO ENVIRONMENTAL ANALYTICAL, GUIDE TO ENVIRONMENTAL ANALYTICAL METHODS 5th Edition