1 Presented at the 20th Annual USEPA National Operator Trainers Conference Buffalo, NY, June 8, 2003. Activated Sludge Microbiology Problems AND Their Control Michael Richard, Sear-Brown Fort Collins, CO CONTENTS I. Introduction II. Microbiology Problems and Their Causes 1.
Poor Floc Formation, Pin Floc and Dispersed Growth Problems Basic floc formation, required for activated sludge operation due to the use of gravity clarifiers, is due to a growth form of many species of natural bacteria. Floc-forming species share the characteristic of the formation of an extracellular polysaccharide ("slime") layer, also termed a