StandardEditionSectionInquiry #QuestionReply520 part II5th - Aug. : sizing methods for PSV s are specified in RP 520 part I, Section , where the combination correction factor (Kc) is when a rupture disk is installed. It may result from the consideration of pressure drop in rupture disk. In other words, a 10% pressure drop is considered for rupture disk. RP 520 part II, Section , states when a PRV is installed on a process line, the 3% limit should be applied. Question: How I can meet the 3% limit when I want to use a rupture disk upstream of the PRV? I think these are contradictory 3% inlet loss rule applies to both liquid and vapor applications. The industry has experienced chatter of PRV s in liquid applications.
Standard Edition Section Inquiry # Question Reply API Standard 520 Part II - Sizing, Selection, & Installation of Pressure Relieving Devices Part II, Installation
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
API Standard 520 - Sizing, Selection, & Installation, API Standard 520 - Sizing, Selection, & Installation of Pressure, SIZING, Selection, Sizing, Selection, and Installation of Pressure-Relieving Devices in Refineries, Installation, Sizing, Selection, and Installation of Pressure, November 2012 Handbook on pressure loss and, November 2012 Handbook on pressure loss and valve sizing, Selection and Sizing of Pressure Relief Valves, Pressure, Equipment Sizing and Capital Cost Estimation, Pentair Pressure Relief Valve Engineering Handbook