APPENDIX A: Culvert Sizing procedures for the 100-Year Peak FlowA. INTRODUCTION Several methods have been developed for estimating the peak flood discharge that can be expected from small ungaged, wildland watersheds. These procedures are useful for determining the size (diameter) of Culvert that should be installed in a stream crossing that is to be constructed or upgraded. Determining the proper size (diameter) Culvert requires: 1) estimating the peak dis-charge of streamflow which would occur at each stream crossing during the 100-year flood, and then 2) determining the size of Culvert which would handle that flow using the Federal Highway Administration (FHWA) Culvert capacity nomograph (FHWA, 1965).