AUGUST 2016 lrfd BRIDGE DESIGN 3-1 Load Factors and Combinations [ ] 3. LOADS AND LOAD FACTORS The loads section of the AASHTO lrfd Specifications is greatly expanded over that found in the Standard Specifications. This section will present applicable loads and provide guidance to MnDOT s practice for the application of these loads. The standard load combinations for lrfd DESIGN are presented in lrfd Table Several of the loads have variable load factors ( , P , TG , SE ). The load factors for permanent loads (P ) typically have two values, a maximum value and a minimum value.
AUGUST 2016 LRFD BRIDGE DESIGN 3-3 [3.4.2] Service I: Load combination used for the design of many elements. It is used for service load stress checks (prestressed concrete), deflection checks, crack control checks in reinforced concrete, etc.