Transcription of Calculating Two-Phase Pressure Drop - River City …
{{id}} {{{paragraph}}}
Chemical Processing, 2000 Fluid Flow 1 of 8 Calculating Two-Phase Pressure DropScott S. Haraburda, PE Engineer, GE Plastics, Mt. Vernon, INAndSteve Chafin Process Engineer, River City Engineering, Lawrence, KSFluid flow concerns are quite prevalent among systems that handle chemicals, either inthe liquid or the vapor state. An important parameter for characterizing the energy of thefluid flowing within a contained system, such as pipes, is Pressure . This pressurebecomes important for designing pipe sizes, determining pump requirements, andaddressing safety concerns. Often the fluid is flowing as both liquid and TypeThe flow type of Two-Phase liquid-gas flow can be characterized into one of seven typesshown in Figure 1.
Chemical Processing, 2000 Fluid Flow Annual http://www.chemicalprocessing.com Page 1 of 8 Calculating Two-Phase Pressure Drop Scott S. Haraburda, PE (scott.haraburda@gepex.ge.com)
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Pressure, Vickers SM4-20 Servo Valves, Eaton Vickers SM4-20 Servo Valves, Pressure drop, API Standard 520 - Sizing, Selection, & Installation, Design Challenges for Recip Compressors in, S XLT Heat Transfer Fluid, XLT HEAT TRANSFER FLUID, XLT† heat transfer fluid, ENGINEERING STANDARD FOR PROCESS DESIGN, Heat Exchangers, Heat Exchangers Heat exchangers, Electric Duct Heaters, Greenheck