CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORSSECTION CHAPTER shall govern the material andinstallation of traps, INTERCEPTORS and 1002 TRAP Fixture plumbing fixture shall be sepa-rately trapped by a liquid-seal trap, except as otherwise permit-ted by this code. The vertical distance from the fixture outlet tothe trap weir shall not exceed 24 inches (610 mm), and the hori-zontal distance shall not exceed 30 inches (610 mm) measuredfrom the centerline of the fixture outlet to the centerline of theinlet of the trap. The height of a clothes washer standpipe abovea trap shall conform to Section A fixture shall not bedouble :1. This section shall not apply to fixtures with A combination plumbing fixture is permitted to beinstalled on one trap, provided that one compartmentis not more than 6 inches (152 mm) deeper than theother compartment and the waste outlets are not morethan 30 inches (762 mm) A grease interceptor intended to serve as a fixture trapin accordance with the manufacturer s installationinstructions shall be permitted to serve as the trap for asingle fixture or a combination sink of not more thanthree compartments where the vertical distance fromthe fixture outlet to the inlet of the interceptor does notexceed 30 inches (762 mm) and thedeveloped lengthof the w
CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the material and installation of traps, interceptors and separators.
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Removal In Wastewater, Removal In Wastewater Treatment Facilities: Construction De, WASTEWATER FACILITIES, Wastewater treatment facilities treatment, Wastewater, States Standards - Recommended Standards for, States Standards - Recommended Standards for Wastewater Facilities, Removal Facilities, Pre-treatment of Textiles Prior to, Reduction of Chloride in Wastewater Effluent With, William E. Dunn Water Reclamation Facility, Removal, Treatment, INTRODUCTION