Transcription of Chapter 12 SEISMIC DESIGN REQUIREMENTS FOR BUILDING …
{{id}} {{{paragraph}}}
P1: 15, 200517:48 Chapter 12 SEISMIC DESIGN REQUIREMENTS FOR BUILDING STRUCTURAL DESIGN Basic SEISMIC analysis and designprocedures to be used in the DESIGN of BUILDING structures and theircomponents shall be as prescribed in this section. The buildingstructure shall include complete lateral and vertical force-resistingsystems capable of providing adequate strength, stiffness, and en-ergy dissipation capacity to withstand the DESIGN ground motionswithin the prescribed limits of deformation and strength DESIGN ground motions shall be assumed to occur along anyhorizontal direction of a BUILDING structure. The adequacy of thestructural systems shall be demonstrated through the constructionof a mathematical model and evaluation of this model for the ef-fects of DESIGN ground motions.
does not apply to the overall design of the seismic force–resisting system. Connection design forces need not exceed the maximum forces that the structural system can deliver to the connection. 12.1.4 Connection to Supports. A positive connection for re-sisting a horizontal force acting parallel …