CHAPTER 6. WALL CONSTRUCTION . SECTION R601 Stud size, height and spacing. The size, height GENERAL and spacing of studs shall be in accordance with Table Application. The provisions of this CHAPTER shall con- trol the design and CONSTRUCTION of all walls and partitions for all Exceptions: buildings. 1. Utility grade studs shall not be spaced more than Requirements. Wall CONSTRUCTION shall be capable of 16 inches (406 mm) on center, shall not support accommodating all loads imposed according to Section R301 more than a roof and ceiling, and shall not exceed 8. and of transmitting the resulting loads to the supporting struc- feet (2438 mm) in height for exterior walls and tural elements.
CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL R601.1 Application. The provisions of this chapter shall con-trolthedesignandconstructionofallwallsandpartitionsforall