1 Chapter 2 DESIGN AND CONSTRUCTION STANDARDS FOR SEPTIC TANKS, SOIL ABSORPTION SYSTEMS, AND OTHER SMALL WASTEWATER SYSTEMS Section 1. Authority. This regulation is promulgated pursuant to the Wyoming Administrative Procedures Act, 16-3-101 et seq.; the Wyoming Environmental Quality Act, 35-11-101 through 35-11-2004; and 35-1-301 through 35-1-309. Specifically, 35-11-301 states that no person, except when authorized by permit, shall: construct, install, modify, or operate any small wastewater facility. 35-11-304 states that to the extent requested, authority to enforce and administer 35-11-30 I (a) (iii) and (v) shall be delegated to qualifying municipalities, water and sewer districts or counties.
trenches of the proposed soil absorption system if there is at least nine (9) feet of spacing between trench sidewalls. (d) For standard soil absorption systems, effective suitable soil depth shall extend at least four (4) feet below the bottom of the soil absorption system to any restrictive layer, fractured rock, or highly permeable material.