Transcription of Directional Control Valves - Border Supply
{{id}} {{{paragraph}}}
Vickers . Valves Directional Control Valves DG3*-H8; 30 and 10 Series, Pilot Operated DG17*-H8; 30 and 10 Series, Manually Operated DG5*-H8; 50 and 30 Series, Solenoid Controlled, Pilot Operated ISO 4401 Size 08. Basic Characteristics Typical Section Mounting .. Surface mounting DG5*-H8-2C Spring-Centered Valve Example Max. pressure: DG*S .. 210 bar (3000 psi). DG*V .. 350 bar (5000 psi). Max. flow .. 700 L/min (185 USgpm). General Description which can be enhanced by optional DG**-H8 Valves are used primarily for stroke and/or pilot choke adjustments. Features and Benefits controlling the starting, stopping and Models include spring offset, spring High pressure and flow capability for direction of fluid flow. centered, pressure centered and maximum cost-effectiveness. detented versions.
DG5*-H8-2C Spring-Centered Valve Example March 1996 GB-2327A Directional Control Valves DG3*-H8; 30 and 10 Series, Pilot Operated DG17*-H8; 30 and 10 Series, Manually Operated
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}