Durco Mark 3 ISO. ISO 2858/5199. Maintenance Checklist Read User Instructions before installing, operating or maintaining this pump. Copies available from Flowserve pump representatives. Specific requirements apply relating to the Product Certification, Permit or Conformity; refer to Conformity document provided with the machine and always consider during change manage- ment on the machine, , when changing a seal. Impeller Clearance1, mm (in) ISO Frame Sizes Impellers Impellers > 260 mm ISO Frame Impeller Shaft Diameter Temp, Impellers Size Drive Thread at the Coupling 211 mm 150 400. C up to to Standard 200 400 1 M 22 24 mm ( in). ( F) 210 mm 260 mm 150 500. 2 M 30 32 mm ( in). 50 3 M 39 42 mm ( in). (122) ( ) ( ) ( ) ( ). 4 M 48 48 mm ( in). 100 (212) ( ) ( ) ( ) ( ). Recommended Torques 150 Screw Torque, (302) ( ) ( ) ( ) ( ) Fastener Size Nm (lbf-ft). 200 M8 16 (12). (392) ( ) ( ) ( ) ( ) M10 25 (18). All except where 250 M12 35 (26). otherwise stated (482) ( ) ( ) ( ) ( ) M16 80 (59).