Expanded Polystyrene (EPS) Insulation Board
4. Projections – Insulation board shall be free of surface projections or wire marks in excess of 1/16 inches (1.6 mm). Packaging All insulation board shall be packaged in polyethylene bags as required by the EIFS manufacturer. Alternative methods of packaging shall be submitted to the EIFS manufacturer and approved in writing prior to use.
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
StoTherm ci XPS Booklet - Sto Corp.
www.stocorp.comAll trim and projecting architectural features must have a minimum 1:2 (27 degree) slope. A minimum of ¾” (19mm) XPS insulation board must remain if areveal is cut in the insulation board. A minimum of 1 ½” thickness of XPS board is needed when a reveal is specified.
StoTherm EIFS: Installation Guide - Sto Corp.
www.stocorp.com2 Stoistheinnovativeworldleaderincladding,coatingandrestorationsystems. StowasanExteriorInsulationandFinishSystemspioneer-introducingStoTherm® toEuropein1963 ...
StoTherm EIFS: Installation Guide - Sto Corp.
www.stocorp.comSto is the innovative world leader in cladding, coating and restoration systems. Sto was an Exterior Insulation and Finish Systems pioneer - introducing StoTherm ® to Europe in 1963. Headquartered in Atlanta, Georgia, ISO 9001:2000 and 14001:2004 Certified Sto Corp., continues to lead the North American industry in
System Bulletin StoPowerwall ExtraSeal - Sto Corp.
www.stocorp.comSystem Bulletin StoPowerwall® ExtraSeal™ Portland cement stucco directly applied to CMU with continuous air and moisture barrier and high performance finish
SAFETY DATA SHEET - Sto Corp.
www.stocorp.com1.3 Details of the Supplier of the Safety Data Sheet . ... for total dust and 5 mg/m of ... are advised to make your own determination as to safety, ...
StoTherm EIFS: Installation Guide - Sto Corp.
www.stocorp.com9 TheStoGuardassemblyconsistsof: Sto Gold Fill ® –Aflexible,trowel-appliedjoint treatmentthat,combinedwithStoGuard MeshorSto DetailMesh,bridgessheathingjointsandprotectsrough
Guide, Installation, Installation guide, Feis, Stotherm eifs, Stotherm
Sto Guide Specification QS200D StoQuik® Silver DrainScreen ...
www.stocorp.comB. APA Engineered Wood Association PS 1 Voluntary Product Standard, Structural Plywood PS 2 Performance Standard for Wood-Based Structural-Use Panels E 30 APA Engineered Wood Construction Guide C. ICC (International Code Council) 2012 and 2015 IBC (International Building Code) D. ICC ES (International Code Council Evaluation Service) ...
Guide, Construction, Woods, Engineered, Engineered wood, Engineered wood construction guide
Sto Gold Coat
www.stocorp.comFluid-applied Vapor Permeable Air Barrier, WRB Technical Data Sto Gold Coat is a fluid-applied vapor permeable air barrier and water-resistive barrier (WRB) with built-in anti-freeze properties. It is used over prepared vertical above grade concrete, concrete masonry, brick masonry, wood and glass mat gypsum sheathing behind StoTherm® ci and other
Job Description Title: Maintenance Mechanical Technician ...
www.stocorp.comJob Description. Title: Maintenance Mechanical Technician Location: Atlanta, GA Plant Reports to: Plant Engineering/ Maintenance Manager Purpose: This position will support operations by maintaining, troubleshooting, repairing and optimizing all facilities and manufacturing equipment including but not limited to:
Title, Maintenance, Mechanical, Descriptions, Job description, Technician, Description job title, Maintenance mechanical technician
Stolit Acrylic Textured Finish - Sto Corp.
www.stocorp.comAbrasion resistance Coverages may vary depending on application technique and surface conditions. Packaging 5 gal pail (19L). Shelf Life 18 months, if properly sealed and stored. Storage Protect from extreme heat [90ºF (32ºC)], freezing, and direct sunlight. REPORT TEST METHOD TEST CRITERIA TEST RESULTS Surface Burning ASTM E-84 < 25 Flame Spread
Related documents
How to Properly Insulate a Slab
www.phrc.psu.eduperimeter slab insulation Heat Loss through an Insulated Slab Windows 33% Roof/Ceiling 8% Slab 15% 6 Doors 5% Walls 39% Insulation and Fenestration Criteria Table 402.1.1 Insulation and Fenestration Requirements by Componenta CLIMATE ZONE FENESTRATION U-FACTORb SKYLIGHTb U-FACTOR GLAZED FENESTRATIONb,e SHGC CEILING R-VALUE WOOD …
TECHNICAL DATA SHEET - Insulation Systems, Commercial ...
www.jm.comfor mechanical insulation systems including pipe, vessels, and equipment. It protects the insulation and underlying pipe/vessel from physical damage, UV exposure, corrosive atmospheres, and water. JM Aluminum jacketing (also called cladding) is available in smooth, stucco embossed, and 3/16 corrugated (cross-crimped) finishes.
THE THICKNESS OF ROCKWOOL INSULATION
www.rockwool.comMinimum insulation thickness for condensation control on ductwork carrying chilled air in ambient conditions: indoor still air temperature 15 13 +25°C, relative humidity 80%, dewpoint temperature 21.3°C 16 14 Indicative thickness of insulation for ductwork carrying warm …
INSULATION OF PIPING & EQUIPMENT (PROJECT …
www.klmtechgroup.comInsulation materials shall have the following properties: - Completely free from all forms of asbestos. - Water-soluble chloride and fluoride ion concentrations as low as possible, 20ppm by mass maximum. - Chemically neutral, with pH preferably between 7 and 8 in the wet condition.