Transcription of FINAL YEAR PROJECT REPORT
{{id}} {{{paragraph}}}
FINAL YEAR PROJECT REPORT UNIVERSITY OF NAIROBI DEPARTMENT OF MECHANICAL AND MANUFACTURING ENGINEERING PROJECT title: DESIGNING A BOILER CHIMNEY HEAT RECOVERY SYSTEM AGAINST FOULING POJECT CODE: FML 01/2014 Submitted by: WANGILA ANTONY BARASA F18/2448/2009 KARANJA SAMSON NGUGI F18/2434/2009 Supervisor: PROF. F. M. LUTI APRIL 2014. You created this PDF from an application that is not licensed to print to novaPDF printer ( )i DECLARATION STATEMENT We declare that any information in this REPORT , except where indicated and acknowledged, is our original work and has not been presented before to the best of our knowledge. WANGILA ANTONY BARASA F18/2448/2009 Date .. KARANJA SAMSON NGUGI F18/2434/2009 Date .. APROVED BY: Prof. F. M. Luti (supervisor) Date of You created this PDF from an application that is not licensed to print to novaPDF printer ( )ii ACKNOWLEDGEMENT We would like to acknowledge with appreciation the valuable guidance from our supervisor, Prof.
v LIST OF SYMBOLS AND ABREVIATIONS. A a: Air side total surface area. A c: Exchanger minimum free flow area. A fr: Heat exchanger frontal area. A g: Gas side total surface area. A: Surface area of the heat exchanger surfaces. C p: Specific heat capacity of air at constant pressure. F: Correction factor for the heat exchanger. H 1: Height of the exchanger core.