FORMALDEHYDE by GC 2541H2C=0 MW: CAS: 50-00-0 RTECS: LP8925000 METHOD: 2541, Issue 2 EVALUATION: PARTIALI ssue 1: 15 May 1989 Issue 2: 15 August 1994 OSHA ppm; 2 ppm ppm; C ppm; carcinogenACGIH:C ppm; suspected human carcinogen(1 ppm = mg/m3 @ NTP)PROPERTIES:gas; vapor density (air = 1); BP C; explosive range 7 to 73% v/v in airSYNONYMS: methanal; formalin (aqueous 30 to 60% w/v HCHO); methylene oxideSAMPLINGSAMPLER: SOLID SORBENT TUBE (10% (2-hydroxymethyl)piperdine on XAD-2, 120 mg/60 mgFLOW RATE: to L/minVOL-MIN: 1 @ 3 ppm -MAX: 36 LSHIPMENT:routineSAMPLE STABILITY:3 weeks @ 25 C [1]FIELD BLANKS:2 to 10 field blanks per setMEDIA BLANKS: 10 per sample setMEASUREMENTTECHNIQUE:GAS CHROMATOGRAPHY, FIDANALYTE:oxazolidine derivative of formaldehydeDESORPTION: 1 mL toluene; 60 min ultrasonicINJECTION VOLUME:1 L splitless; split vent time 30 secTEMPERATURE-INJECTOR: 250 C)
3. Sample at an accurately known flow rate between 0.01 and 0.10 L/min for a total sample size of 1 to 36 L. NOTE: Formaldehyde reacts with 2-(hydroxymethyl)piperidine on the sorbent bed during sampling. Sampling rate is limited by the speed of this reaction. Sampling above 0.10