GUIDELINES FOR. TEMPORARY SHORING . EMAIL BEFORE YOU DIG CALL BEFORE YOU DIG. 1-800-533-2891. EMERGENCIES EMERGENCIES. 1-888-877-7267 1-800-832-5452. Contents 1. INTRODUCTION ..2. PURPOSE ..2. SCOPE ..2. 2. GENERAL CRITERIA ..2. SAFETY & RAILROAD OPERATIONS ..2. SHORING REMOVAL ..2. RAILROAD FLAGGING ..2. CALL BEFORE YOU DIG & EXISTING UTILITIES ..3. APPLICANT & CONTRACTOR RESPONSIBILITIES ..3. TRACK, GROUND & SHORING MONITORING: ..4. RAILROAD RIGHT-OF-WAY ..5. CONSTRUCTION AND maintenance AGREEMENT ..5. RAILROAD REVIEW PROCESS ..5. APPROVAL 3. DESIGN ..6. GENERAL DESIGN REQUIREMENTS ..6. INFORMATION REQUIRED ..8. DESIGN PROCEDURE ..9. (Step 1) EXCAVATION LOCATION ..9. (Step 2) SUBSURFACE CHARACTERIZATION ..9. (Step 3) SHORING TYPES .. 11. (Step 4) APPLIED LOADS AND CALCULATIONS .. 12. (Step 5) STRUCTURAL DESIGN CALCULATIONS .. 19. DESIGN PLAN REQUIREMENTS .. 23. 4. DEFINITIONS .. 24. 5. APPENDIX .. 26. LIVE LOAD PRESSURE DUE TO COOPER E80 LOADING.
d. These guidelines supplement the current American Railway Engineering and Maintenance-of-Way Association (AREMA) Manual for Railway Engineering. For items covered within these guidelines and AREMA, the more restrictive shall control. i. It is the requirement for the Contractor and designer developing Railroad shoring systems to
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
GUIDELINES FOR THE PLANNING, INSTALLATION, Guidelines for the Planning, Installation and Maintenance of, Planning, Installation, Guidelines, Maintenance, And maintenance, USPS, Architectural Heritage Protection Guidelines, Architectural heritage protection, BOILER, Installation Rules, GUIDELINES FOR THE CONSTRUCTION OF EARTH-FILL, GUIDELINES FOR THE CONSTRUCTION OF EARTH-FILL DAMS, Construction of earth-fill dams