Transcription of HANDBOOK - michigan.gov
{{id}} {{{paragraph}}}
1 Permit to Install EXEMPTION HANDBOOK michigan Air Pollution Control Rules R (Rules 278 291) michigan Department of Environmental Quality (800) 662-9278 January 2017 2 Significance Levels (From Rule 119) Air Contaminant Emission Rate carbon monoxide 100 TPY nitrogen oxides 40 TPY sulfur dioxide 40 TPY Particulate matter 25 TPY PM-10 15 TPY 10 TPY Volatile organic compounds 40 TPY Lead TPY Fluorides 3 TPY Sulfuric acid mist 7 TPY Hydrogen Sulfide (H2S) 10 TPY Total reduced sulfur compounds (including H2S) 10 TPY Reduced sulfur compounds (including H2S) 10 TPY Municipal waste combustor organics, measured as total tetra- through octachlorinated dibenzo-p-dioxins and dibenzofurans Mg/year or TPY Municipal waste combustor metals (as PM) 14 Mg/year or 15 TPY Municipal waste combustor acid gases (measured as SO2 and HCL) 36 Mg/year or 40 TPY Municipal solid waste landfill emissions (measured as nonmethane orga)
2 Significance Levels (From Rule 119) Air Contaminant Emission Rate Carbon monoxide 100 TPY Nitrogen oxides 40 TPY Sulfur dioxide 40 TPY Particulate matter 25 TPY
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
CERTIFIED REFERENCE MATERIALS AND REFERENCE, CERTIFIED REFERENCE MATERIALS AND REFERENCE SAMPLES, Sulfur, Combustion Analysis Basics, Materials Compatibility Guide, Reference, MATERIAL SAFETY DATA SHEET, Flue gas, A707/A707M-02 Standard Specification, Handbooks of Monochromatic XPS Spectra, Rosemount 3051S April 2007