INTELLIKNIGHT 5820XL - Silent Knight
Addressable Fire System ... photoelectric types, have sensing limitations. No type of smoke detector can sense every kind of fire caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials,
Tags:
Addressable, Intelliknight, Photoelectric, Intelliknight 5820xl, 5820xl
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
IntelliKnight 5808 Single Loop Addressable Fire …
www.silentknight.comIntelliKnight® 5808 Single Loop Addressable Fire Alarm Control System IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator
Loops, Control, Fire, Single, Lamar, Addressable, Intelliknight 5808 single loop addressable, Intelliknight, 5808, 174 5808 single loop addressable fire alarm control, Loop addressable fire alarm control
SILENT KNIGHT MODEL 5207
www.silentknight.comFire Control / Communicator Rev. C, 04/03 Part Number 150865 SILENT KNIGHT MODEL 5207 Installation, Programming, and Operation Manual
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE …
www.silentknight.comcalifornia department of forestry & fire protection office of the state fire marshal fire engineering - building materials listing program listing service
Programs, Department, Engineering, Material, Building, California, Fire, Forestry, Listing, California department of forestry, Fire engineering building materials listing program
6700 - silentknight.com
www.silentknight.com• Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single-point access using the
SILENT KNIGHT MODEL 5207
www.silentknight.com150865 1-1 Section 1 Introduction The Model 5207 is an 8-zone fire alarm control panel (expandable up to 16 zones) with a dig-ital communicator that meets NFPA 72 requirements.
Model 5208 Fire Alarm Control Panel with Digital Communicator
www.silentknight.com• Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions • Programmable AC trouble relay • Built-in synchronization for appliances from AMSECO ®,
Related documents
TrueAlarm Analog Sensors – Photoelectric and Heat ...
www.simplex-fire.comTrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control unit every four seconds. You can easily interchange different TrueAlarm sensor types to meet specific location ...
MORLEY-IAS FIRE DETECTION AND ALARM SYSTEMS
www.honeywellbuildings.inNON-ADDRESSABLE FIRE DETECTION AND ALARM SYSTEMS FIRE ALARM CONTROL PANELS 5-6 NON ADDRESSABLE DEVICES 7-21 ... The combination of photoelectric and thermal characteristics provides a faster response to ‘real fire’ situations, while at the same time reducing the risk of unwanted alarms.
System, Fire, Lamar, Addressable, Detection, Photoelectric, Fire alarm and detection systems, Addressable fire detection and alarm systems
Intelligent Non-Relay Photoelectric Duct Smoke Detector
www.systemsensor.com(addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFlex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased
H365 Series - Fire-Lite
www.firelite.comAddressable Heat Detectors Addressable Devices DF-61011:C The Fire•Lite® Alarms H365(A), H365R(A), and H365HT(A) addressable plug-in thermal detectors are designed for both perfor-mance and aesthetics and are a direct replacement for the H355 Series. A new modern, sleek, contemporary design and advanced
4007ES Fire Detection and Control with Addressable ...
simplex-fire.comAddressable initiating device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to
FSP-951 - Control Fire Systems
www.controlfiresystems.comFSP-951: White, low-profile intelligent photoelectric sensor, FlashS-can only. FSP-951A: Same as FSP-951 but with ULC listing. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. FSP-951A-IV: Same as FSP-951-IV but with ULC listing. FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal ...
FSP-851, FSP-851T, & FSP-851R - Control Fire Systems
www.controlfiresystems.comable level. The FSP-851 photoelectric detector’s unique optical sensing chamber is engineered to sense smoke pro-duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sens-ing on the FSP-851T. The FSP-851R is a remote test capable detector for use with DNR(W) duct detector housings.