LOGIC FLUE & ACCESSORIES GUIDE. - Ideal Heating

LOGIC FLUE & ACCESSORIES COMBI CLOGIC COMBI ESP1 LOGIC + COMBI CLOGIC SYSTEM SLOGIC+ SYSTEM SLOGIC HEAT HLOGIC+ HEAT HLOGIC CODE COMBI ESP1 This manual is for guidance only and must be read in conjunction with the Installation and Servicing instructions supplied with the SITING21315/16121262/371568/914714106111 1 There are a substantial number of flue options available with the Ideal ranges, giving excellent siting flexibility for almost all range of options include standard and telescopic flues as well as roof flue and powered vertical flue ensure siting issues are kept to a minimum, High Level Flue Outlet kit options and Flue Deflector kits are available. FLUE TERMINAL POSITIONMIN. SPACING1. Directly below, above or alongside an opening window, air vent or other ventilation (12")2. Below guttering, drain pipes or soil 200825mm (1")*75mm (3")3. Below 200825mm (1")*200mm (8")4. Below balconies or car port 200825mm (1")*200mm (8")5. From vertical drain pipes or soil 200825mm (1")*150mm (6")6.

From an internal or external corner or to a boundary alongside the terminal. BS5440-1 2008 25mm (1")* 300mm (12") 7. ... (Measured from centreline of the turret to the outside of the wall terminal) 90° Elbow Kit 60/100 - (Equivalent flue length resistance = 1M)