Manual: 92B Pressure Reducing Valve - Emerson

Instruction Manual Form 1329. Type 92B. October 2014. Type 92B Pressure Reducing Valve ! Warning Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion, fire and/or chemical contamination causing property damage and personal injury or death. Fisher regulators must be installed, operated and maintained in accordance with federal, state and local codes, rules and regulations and Emerson Process Management Regulator Technologies, Inc. ( Emerson ) instructions. If the regulator vents gas or a leak develops in the system, service to the unit W8264. may be required. Failure to correct trouble could result in a hazardous condition. Figure 1. Type 92B Pressure Reducing Valve Installation, operation and maintenance dirty operating environments while providing accurate procedures performed by unqualified and stable Pressure control. The Type 92B is applied personnel may result in improper as a main Pressure Reducing Valve in industrial adjustment and unsafe operation.

Type 92B 3 Principle of Operation Refer to the operational schematic in Figure 2. Compression of the pilot spring pushes the diaphragm down and holds the pilot valve plug open.