Mark II Series Molded Plastic Manometers

Bulletin D-58. Mark II Series Molded Plastic Manometers Specifications - Installation and Operating Instructions 1-7/16 3-11/16. 1-1/4 [ ] [ ] 7/32 [ ] HOLE. 5/8. [ ] [ ]. 5-29/32. 4-25/32 [ ]. [ ]. 25/32 4-23/32. [ ] [ ]. 1-1/8. [ ] 25/32 [ ] 7/32 X 13/32. 7-13/32 [ ] [ X ]. 2-1/4 MOUNTING SLOT. [ ] MAX. Mark II Model No. 25 inclined-vertical manometer, (shown with optional A-612 portable stand). dwyer Mark II Manometers come in a variety of ranges. Make SPECIFICATIONS. sure the fluid being used is for the correct manometer. Accuracy: 3% FS. Temperature Limits: 140 F (60 C). Pressure Limits: 10 psi (70 kPa). Mark II #25, 27, MM-80 and M-700 Pa use red gage fluid Weight: lb (472 g). (specific gravity ). Mark II #26, 28 and MM180 use blue gage fluid (specific gravity MAINTENANCE. ). Check fluid level regularly and adjust zero with zero adjust knob. Be sure tubing connections are disconnected and gage is open If additional fluid is required, call, fax or email the dwyer office to atmosphere before adjusting zero.

Mark II Series Molded Plastic Manometers Specifications - Installation and Operating Instructions Bulletin D-58 DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.com