-1-California Test 301 STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCYM arch 2000 DEPARTMENT OF TRANSPORTATION ENGINEERING SERVICE CENTER Transportation Laboratory 5900 Folsom Blvd. Sacramento, California 95819-4612 METHOD FOR DETERMINING THE RESISTANCE R VALUE OF TREATED AND UNTREATED BASES, SUBBASES, AND BASEMENT SOILS BY THE STABILOMETER CAUTION:Prior to handling test materials, performing equipment setups, and/or conducting this METHOD , testers are required to read SAFETY AND HEALTH on Page 3, Section D of this METHOD . It is the responsibility of the user of this METHOD to consult and use appropriate safety and health practices and determine the applicability of regulatory limitations before any testing is performed.
Moisture exudation indicating device consisting of a detection plate and display panel (Figure 6) and conforming to the ... seated and free acting upper head conforming to the requirements of California Test 108. The machine must ... medium-fast filtering speed, medium retention. S&S Sharkskin general