NI 6351 Device Specifications - National Instruments

Device SPECIFICATIONSNI 6351X Series Data Acquisition: MS/s, 16 AI, 24 DIO, 2 AOThe following Specifications are typical at 25 C, unless otherwise noted. For moreinformation about the NI 6351, refer to the X Series User Manual available from InputNumber of channels8 differential or 16 single endedADC resolution16 bitsDNLNo missing codes guaranteedINLR efer to the AI Absolute accuracy rateSingle channel MS/sMultichannel maximum (aggregate) MS/sMinimumNo minimumTiming resolution10 nsTiming accuracy50 ppm of sample rateInput couplingDCInput range V, V, V, 1 V, 2 V, 5 V, 10 VMaximum working voltage for analoginputs (signal + common mode) 11 V of AI GNDCMRR (DC to 60 Hz)

Accuracy Refer to the AO Absolute Accuracy table. Maximum update rate 1 channel 2.86 MS/s 2 channels 2.00 MS/s Timing accuracy 50 ppm of sample rate Timing resolution 10 ns 6 | ni.com | NI 6351 Specifications