NYC Energy Conservation code Commercial Alterations Photo: Samantha Modell Bill de Blasio Mayor Rick D. Chandler, PE Commissioner Version 1 | NYC Energy Conservation code Commercial Alterations Under the NYC Energy Conservation code (NYECC or Energy code ), there are two types of existing commercial buildings: 1. Non-residential buildings; and 2. Residential buildings higher than three stories (even if they contain no commercial usage). Alterations affecting the building 's thermal envelope, mechanical systems, service water heating systems and permanently installed lighting and power systems must comply with the Energy code . Use a tabular analysis, COMcheck software or DOE2 Energy modeling software to demonstrate compliance. building Envelope The NYCECC provides minimum standards for thermal ratings requirements of: building walls;. Floors;. Roofs;. Windows;. Skylights; and Doors.
NYC Energy Conservation Code Commercial Alterations BUILD SAFE | LIVE SAFE 06.2015 | 2 of 10 Under the NYC Energy Conservation Code (NYECC or Energy Code), there are two types of existing commercial buildings:
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Energy, Consumption, Information, LOCAL LAWS 88 of 2009, Lecture Notes, Best Practices Guidance for Providing, Best Practices Guidance for Providing Business, Laboratories for the 21st Century, Introduction to Low-Energy Design, Plaster Assemblies, Projects & Proposals Citywide Zone Green, Projects & Proposals > Citywide Zone Green, Buildings