Transcription of Reverse Osmosis Optimization - Energy
{{id}} {{{paragraph}}}
Reverse Osmosis Optimization Prepared for the Department of Energy Federal Energy Management Program By Pacific Northwest National Laboratory K. L McMordie Stoughton, X. Duan, and Wendel August 2013 Contacts Will Lintner, ., CEM Federal Energy Management Program Department of Energy 1000 Independence Ave. SW Washington, DC 20585-0121 Phone: (202) 586-3120 E-mail: Kate McMordie Stoughton Pacific Northwest National Laboratory Box 999 Richland, WA Phone: (888) 375-7665 E-mail: Cover photo: Reverse Osmosis system at Sandia National Laboratories. i Acknowledgements The authors of this report would like to thank the following individuals that provided support to the production of the technology evaluation.
Wastewater treatment costs also may be reduced if there is a reduction in ... boiler feed water filtering, product rinsing, microelectronics production, laboratory ... CA membranes are tolerant to oxidizing chemicals such as chlorine but can be vulnerable to compaction (where the membrane is compressed) at high pressures, which ...
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
CHAPTER 39 BOILER WATER TREATMENT, Feed water treatment chemicals, Feed water, Control, Boiler, Boiler feed water, Water treatment, Boiler feed water treatment, Chemicals, Treatment, TOTAL DISSOLVED SOLIDS, Water treatment chemicals, Boiler water, In Water Treatment Processes, Boiler Water Treatment, Water