RSC - SOFIMA HYD

RSCTANK INSERT RETURN FILTER, INSIDE TO OUTSIDE FILTRATION1 MPa (10 bar)RSC Flow rates: 20 2400 l/minTECHNICAL DATAMax. working pressure: 1 MPa (10 bar)Max. testing pressure: 2 MPa (20 bar)Bursting pressure: 3 MPa (30 bar)Fatigue test: 0 500 kPa (5 bar) / cyclesBypass valve: p 170 kPa (1,7 bar) 0,2 Filter element collapse pressure: p 1 MPa (10 bar)Working temperature: -25 +110 CMATERIALSE lement support: size 100 - 200 polyamidesize 300 aluminiumDiffusor: zinc plated steelMagnetic core: syntherized magnetic materialSeals: standard NBR on request FKM COMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.

RSC CRC 110 120 130 140 220 230 240 Bypass type F 10 kPa (1 bar) F F F F F F F Bypass type F 10 kPa (1 bar) F F F F F F F F FC FD F CD RT MS FC m(c) FD 12m(c) F 21m(c) CD 10