LFM - SOFIMA HYD

LFMSUCTION OR LOW PRESSURE INLINE FILTERLFM0,7 MPa (7 bar)Port sizes: 3/8 1 1/2 Flow rates: 4 600 l/minTECHNICAL DATAMax. working pressure: 0,7 MPa (7bar)Max. test pressure: 1,4 MPa (14 bar) Bursting pressure: 2,1 MPa (21 bar)Filter element collapse pressure: p 400 kPa (4 bar) - ISO 4572 Working temperature: -25 +110 CMATERIALSHead: aluminiumBowl: cold formed steelSeals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.

lfm 010 050 070 120 cle 180 rd mv cd cv ms mn rd = 10µ mv = 25µ cd = 10µ cv = 25µ ms = 60µ mn = 125µ rd = 10µ rv = 25µ cd = 10µ cv = 25µ ms = 60µ mn = 125µ