Example: dental hygienist

LFM - SOFIMA HYD

LFMSUCTION OR LOW PRESSURE INLINE FILTERLFM0,7 MPa (7 bar)Port sizes: 3/8 1 1/2 Flow rates: 4 600 l/minTECHNICAL DATAMax. working pressure: 0,7 MPa (7bar)Max. test pressure: 1,4 MPa (14 bar) Bursting pressure: 2,1 MPa (21 bar)Filter element collapse pressure: p 400 kPa (4 bar) - ISO 4572 Working temperature: -25 +110 CMATERIALSHead: aluminiumBowl: cold formed steelSeals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.

lfm 010 050 070 120 cle 180 rd mv cd cv ms mn rd = 10µ mv = 25µ cd = 10µ cv = 25µ ms = 60µ mn = 125µ rd = 10µ rv = 25µ cd = 10µ cv = 25µ ms = 60µ mn = 125µ

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of LFM - SOFIMA HYD

1 LFMSUCTION OR LOW PRESSURE INLINE FILTERLFM0,7 MPa (7 bar)Port sizes: 3/8 1 1/2 Flow rates: 4 600 l/minTECHNICAL DATAMax. working pressure: 0,7 MPa (7bar)Max. test pressure: 1,4 MPa (14 bar) Bursting pressure: 2,1 MPa (21 bar)Filter element collapse pressure: p 400 kPa (4 bar) - ISO 4572 Working temperature: -25 +110 CMATERIALSHead: aluminiumBowl: cold formed steelSeals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test.

2 For further information contact our Technical = 10 MV = 25 CD = 10 CV = 25 MS = 60 MN = 125 RD = 10 RV = 25 CD = 10 CV = 25 MS = 60 MN = 125 RDMVCDCVMSMNRDMVCDCVMSMNRDMVCDCVMSMNRDMV CDCVMSMN00 = Without00000121 = NBR Nitrile2 = FKM Fluoroelastomer1 = NBR Nitrile2 = FKM Fluoroelastomer12121212B = BSPN = NPTBNBNBNBNBN23----2 = 3/8 3 = 1/2 4 = 3/4 5 = 1 6 = 1 1/47 = 1 1/2--4-------6------7---5--0E = nr. 2 ports 1/8 , plugged33 = Pressure gaugeP1 = Pressure switch11 = Vacuum gauge91 = Vacuum switch0E33P111 910E33P111 910E33P111 910E33P111 910E33P111 91 XXXXXX = No accessory availableXXXXXXXXS tainless steel wire meshSteel wire meshPaperStainless steel wire meshSteel wire meshPaperTypeTypeFilter mediaFilter mediaBypass typePortsPort sizeSealsIndicatorsSealsAccessoriesRetur n lineSuction lineHOW TO ORDER THE COMPLETE FILTERHOW TO ORDER THE FILTER ELEMENTI ndicator PortIndicator PortL2L3L1D3D2H5D1H2H3H4RH1(return low pressure)(suction)

3 TypeLFM 050 LFM 070 LFM 120 LFM 180 3/8 1/2 3/4 1 1 1/41 1/21701702452852903452222373740403838393 95050959513513518518550501001001501506,5 6,58,58,510,510,581811141141551551051051 4014017817813213220624624029526262424282 82020252525251,01,02,02,56,06,5D1H1H2H3L 1D2D3H4L2H5 RWeightKgL3 DIMENSIONAL LAYOUT(mm)CLOGGING INDICATORSS cale 0 1,2 MPa (12 bar)Setting 150 kPa (1,5 bar)RETURN LINENBRNBRFKMFKM33P1--Pressure gaugePressure switchATEX 3 GD EEx e T69771/8 24 Setting 20 kPa (0,2 bar)SUCTION LINE9771/8 24 NBRNBRFKMFKM1191--Vacuum gaugePressure switchATEX 3 GD EEx e T6132 SPDT, 30V: > max resistive or inductive load 3A - 1A 125 or 250V: > max resistive or inductive load 3A - 0,5A respectivelyProtection IP65 - Connector DIN 43650 SPDT, 30V: > max resistive or inductive load 3A - 1A 125 or 250V: > max resistive or inductive load 3A - 0,5A respectivelyProtection IP65 - Connector DIN 43650 Scale 0 100 kPa (1 bar) 401/8 2511123 40251/8 11 Type5 kPa(0,05 bar)10 kPa(0,1 bar)20 kPa(0,2 bar)40 kPa(0,4 bar) p.

4 LFM 050 RDMVCDCVMSMNRDMVCDCVMSMNRDMVCDCVMSMN6746 8891181011121921171923341113101314191618 1517192746583645617225302327323834402936 4553921027291110132475845556272617558727 995152177132148185197 FilterMediaType p ..LFM 070 LFM 120 LFM 180 RDMVCDCVMSMNRDMVCDCVMSMNRDMVCDCVMSMN3235 2730414575914561106136158207871402353297 0735368769812217510211720125428533017027 6386454135158110132167197295337227273367 4014055103144625796172283491852202653034 40535386428556590572638503628749783 FilterMediaTechnical data subject to variations without prior notice. LFM 02/2016 FLOW RATES(l/min)FILTER AREA(cm2)5 kPa(0,05 bar)10 kPa(0,1 bar)20 kPa(0,2 bar)40 kPa(0,4 bar)118018302405444063838661067163732883 8428661067163732883842 CLE 010 CLE 050 CLE 070 CLE 120 CLE 1801180183024054440638347273216372055295 5472732163717262482 CDMVRDCVMSMNTypeThe reference fluid has a kinematic viscosity of 30 cSt and a density of 0,86 different oil viscosity please contact our Sales Department for further information.