Transcription of Soil Density - Standard vs Modified Proctor
{{id}} {{{paragraph}}}
2003 Keystone Retaining Wall Systems912/30/03 soil Density - Standard vs Modified ProctorReinforced soil structures routinely specify that all soils be compacted to 95% of the maximumdensity determined by ASTM D698 - Standard Proctor Densityfor conformance with thedesign. However, Standard Proctordensity criteria is typically utilized in the Eastern US where-asModified Proctordensity criteria is typically utilized in the Western US which can createsome conflicting specification has been done showing the relationship betweenStandardandModified Proctordensi-ty testing for different soils types as indicated below:140130120110100908070 , water content in %05101520253035A1B1C1A2B2C2A3B3C3A- Modified ProctorB- Standard ProctorC- 15 blow ProctorSoil 2(Sand) soil 1(Silty Sand)So il 3(Clay)Moisture- Density Relationships(Ref.)
Soil Density - Standard vs Modified Proctor Reinforced soil structures routinely specify that all soils be compacted to 95% of the maximum density determined by ASTM D698 - Standard Proctor Density for conformance with the design. However, Standard Proctor density criteria is typically utilized in the Eastern US where-
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Compaction, Standard Proctor Test, Moisture-Density Relationships by Use, Proctor test, Part 3 COMPACTION TESTS, Proctor standard, Proctor Compaction test, Part 4 COMPACTION TESTING, Proctor, Standard Proctor, CIVL354-notes-1- Soil compaction.ppt, Test, Soil Compaction, Test STANDARD, Construction Planning, Equipment, CHAPTER, Standard Test, Standard Test Methods for Laboratory Compaction Characteristics of Soil, Compaction test, Standard, Compaction of Fine- Grained Soils Using the Proctor, CHAPTER 7 CORRECTING DENSITY TESTS FOR MATERIAL