Transcription of TECH BULLETIN 053 - Cat Pumps
{{id}} {{{paragraph}}}
LO-PRESSURE SEAL (View 1)Before fitting Lo-pressure seal into inlet manifold, apply liquid gasket in the manifold bores where the seals will make contact with the manifold chamber walls. Remove EXCESS liquid SEAL (View 2)Apply liquid gasket in the manifold chamber walls where the Hi-pressure seal will make contact when installed. See individual pump service manual for correct seal installation procedure. Remove EXCESS liquid AND FEMALE ADAPTERS (View 3)Apply liquid gasket to the V of the female adapter and to the manifold chamber or V-Packing cylinder where the V-Packings will make contact. Apply liquid gasket to the V of the male adapter and to the manifold chamber walls where the male adapter comes in contact. Remove EXCESS liquid on other : liquid Gasket - Plunger Pump Models For aggressive liquid applications such as car wash, reverse osmosis, leachate, and saltwater enhance the life of Pumps used with aggressive liquids, liquid gasket should be applied to certain mating surfaces during maintenance.
LO-PRESSURE SEAL (View 1) Before fitting Lo-pressure seal into inlet manifold, apply liquid gasket in the manifold bores where the seals will make contact
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
McDonnell & Miller Gasket Selector Guide, GASKET, Liquid, BASIC GASKET APPLICATION GUIDE & MATERIAL, BASIC GASKET APPLICATION GUIDE & MATERIAL SELECTION, Magnetic Liquid-Level Gauges for, AIR-COOLED SCREW LIQUID CHILLERS, Liquid Containment, Gasket Selection Guide B-03, Liquid Filtration Accessories, MAINTENANCE MANUAL, 1590BFL