{{id}} {{{paragraph}}}
Process DisplayRIA 250 Multifunctional 1 channel Display withuniversal input, loop power supply, alarm limits,and analog outputApplication Areas Plant and machine construction Control panels Laboratory fittings Temperature Display and monitoring Process Display and monitoring Process control Signal match and transformingAdvantages Multi functional:All normal measurement signals canbe directly connected (bipolar voltageand current, thermocouple, RTD) Display :Active numeric measured valuedisplay with bar graph Alarm:Flexible set point monitor with2 relay contacts Active:Adjustable current or voltage analogoutput Power:Integrated loop power supply forconnected sensors Communicative:RS 232 interface for set-upconfiguration and measured valueoutputTechnical InformationTI 060R/24/aeThe Power of Know How2 FunctionsThe presettable universal input enablesdirect connection of various sensors,including current, voltage, RTD andthermocouples.