SectionEditionInquiry InquirySCAST ReponseMultipleEd 12, Ad 0650-2013-F8 May ASTM A500 cold formed round structural tubing be substituted for ASTM A53 pipe for round structural members such as floating roof legs, for roof support columns, etc?Yes subject to the provisions of Para. , including - Nov. 1998Do the current rules in API 650 allow for a carbon steel tank to incorporate stainless steel components such as nozzles or an entire shell ring, provided all requirements of API 650 are followed for each of the particular material types (CS or SS) used in the structure?No. For a carbon steel tank, API 650 does not allow the use of materials that do not comply with the specifications listed in Section - May 1993 Does API 650 permit the substitution of Charpy impact testing in lieu of meeting specified chemistry requirements?
Section Edition Inquiry No. Submitted Inquiry SCAST Reponse 2.7 9th - May 1993 Referring to API 650, Section 2.7, are bolt heads required to be marked according to ASME Section II, Part A for
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
API Standard 653, American Petroleum Institute, API Standard 653 Tank, Mechanical integrity management of bulk storage, 200120803 API RP 545 Revision, Atmospheric Above Ground Tank Storage, DEC Program Policy, Standard, 653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION, Installation of an aluminum internal floating, Tank, Tank Lifting and Stabilization, Tank Lifting and Stabilization Tank, Spill Prevention, Control and Countermeasure Plan