Technical ManualPart 4: Wall & Floor Panel Design & ConstructionCSR Hebel Technical Manual August 2010 7 Wall & Floor Panel Design & Construction Overview This section outlines the many factors to be considered when designing building solutions from CSR Hebel autoclaved aerated concrete (AAC) panels, and provides design tables and charts to assist the designer. The CSR Hebel panels can be group into four basic types relating to application, these types being: Floor panels; Wall panels; Ceiling panels; and Roof section has been broken into fourmajor areas as follows:Background Applications Design Information for CSR Hebel AACP anel Behaviour of a CSR Hebel Panel SystemsDesign of CSR Hebel AAC Panels Floor Panels Wall Panels Ceiling Panels Roof PanelsThis section includes; benefits, design andconstruction considerations, foundationsand movement joint requirements, designprocedures
such as blockwork infill between the structural frame. • Control joints (C.J.), (one type is an expansion joint), are provided to relieve the induced stresses resulting from thermal expansion or contraction of the AAC, or differential movement between the AAC and another material or structure, such as abutting walls or columns of concrete or ...