Technical ResearchProper Cure ofVinyl Ester ResinsINTERPLASTIC CORPORATIONT hermoset Resins DivisionCoREZYN Premium Vinyl Ester MoleculeComplete cure of a resin is critical to achieving theoptimum corrosion resistance and physical proper-ties of a laminate. Typical composites are made inthicknesses ranging from in. ( mm) in. ( mm). Previous work has shown thathigher catalyst levels yield a higher degree of curefor thin panels made at 77 F (25 C). However,fiberglass reinforced plastic/glass reinforced plastic(FRP/GRP) products are made under a variety oftemperatures and cure conditions. This study wasdone to help FRP/GRP manufacturers addressparameters that they can control to make qualityparts under a variety of parameters were evaluated in a designedexperiment. These parameters are critical to making a quality part in hand lay-up, spray-up andother processes. Two of the controllable parame-ters are catalyst and promoter levels. The thirdparameter, temperature, is independent of the othertwo.