Transcription of TRENCH SECTION (TYPICAL)
{{id}} {{{paragraph}}}
AB 6"MIN6"MIN12"MINGROUND OR PAVEMENT SURFACESHEATHING AS REQUIRED BY PLAN,SPECIFICATIONS OR WISCONSINADMINISTRATIVE CODESEE SPECIFICATIONS FOR FILL MATERIALCOVER MATERIALBEDDING MATERIAL TO BE PLACED BEFORESETTING PIPE:x4" MIN UNDER BARRELx3" MIN UNDER BELLA = bedding MATERIAL LIMITS FOR PVC,CORRUGATED POLYETHYLENE, POLYPROPYLENE& POLYMER MORTAR PIPEB = bedding LIMITS FOR CONCRETE PIPEBELL AND SPIGOT JOINT SHOWN3" CRUSHED AGGREGATE BASE REQUIRED IN WETTRENCH. COST TO BE INCIDENTAL TO SEWERINSTALLATIONTONGUE AND GROOVE CROSS SECTION (EXAGGERATED)BELL AND SPIGOT CROSS SECTION (EXAGGERATED)DRY TRENCHWET TRENCHDRY TRENCHWET TRENCHREVISED 02/27/14 BY NWJ:\CITYDWG\Civil 3D Drawings\DTL\City SDDs\ TRENCH SECTION SECTION (TYPICAL)SCALE 1" = 1'CONCRETEPAVEMENTASPHALTOVERLAYASPHALT PAVEMENT,CONCRETE PAVEMENT ORCONCRETE BASEEXISTING GROUNDEXISTING GROUNDPIPESTANDARD TRENCH SECTION ASREQUIRED BY PLANS ANDSPECIFICATIONSPAVEMENT SAWCUT - T
bedding material native ground attach drop to mh wall with strapping anchored with masonry fasteners (min. 2 straps per drop) shim as necessary. whenever "x" is greater than 2 ft. an outside drop must be constructed as shown. flow note: fl of drop to be set at same elev. as spring line of main 4'-0" c.c. 8" min. drop pipe to be same diameter as ...