Transcription of U.S. Pipe TR Flex®
{{id}} {{{paragraph}}}
Pipe TR Flex Pipe & FittingsCONTENTSGENERAL INFO Pipe 4" 36" 2 Suggested Specification Wording 3 ASSEMBLY INSTRUCTIONS Pipe & Fittings 4 Pipe & Fittings 4" 10" 6 Pipe & Fittings 12" 20" 7 Pipe & Fittings 24" 36" 8 Pipeline Expansions 9 Field Cut Pipe 10 Gripper Rings 12 Gripper Rings Layout 13 Gripper Rings Installation 14 Notes 18 SPECIFICATIONS Basic Dimensions 21 Pressure Class (Nominal thickness for standard pressure classes of ductile iron pipe) 22 Pressure Class (Thickness, Dimension & Weight) 23 Thickness Class (Thickness, Dimension & Weight) 24 Rubber Locking Segment Retainers 27 SPECIFICATIONS - FITTINGS Bends (Thickness & Dimensions) 28 Te es (Thickness & Dimensions) 32 Tees with Flange Branch 35 Crosses 37 Wye Branches & Wyes 39 Concentric Reducers 41 Eccentric Reducers 43 Flange Connecting Pieces 44 Telescoping Sleeves 45 Sleeve/Connecting Pieces 46 SPECIFICATIONS - ACCESSORIES Caps & Plugs Pipe A Forterra CompanyTR FLEX PIPE & FITTINGSANSI/AWWA STANdArdSANSI/AWWA C151 Ductile-Iron Pipe, Centrifugally Cast, for outside coating and inside lining are in accordance with ansi /AWWA C151 C153 Ductile-Iro
Flex Gripper Ring, TR Flex Pipe field weldments or approved equal. Cement mortar lining and seal coating for pipe and fittings, where applicable, shall be in accordance with ANSI/AWWA C104/A21.4. Asphaltic outside coating shall be in accordance with ANSI/AWWA C151/A21.51 for pipe and ANSI/AWWA C110/A21.10 or ANSI/AWWA C153/A21.53 for fittings.