TI Designs Ultralow Power Multi-sensor data Logger with NFC. Interface Reference Design Design Overview Design Features TIDA-00524 provides a complete reference design > 5 Year Battery Life on a CR2032 coin cell for asset tracking and cold chain data logging with RF430CL33xH NFC Dynamic Tag Type 4B. over 5 year battery life and a simple NFC (Near Field Compliant Communication Communication) interface for configuration and read NFC configuration and data read back back. For maximum flexibility, the system offers the Multiple sensor Options choice of multiple sensor configurations to monitor - Temperature (TMP112). temperature (TMP112), ambient light (OPT3001), - Temperature + Ambient Light and/or humidity (HDC1000).