Voltage Limiting Devices Combined with SPDFor electric railway system09 / 2016 VLD-O (BVL-100-120-R01) protects person from excessively high touch Voltage at railway station. Cited from EN of exposed metal parts at railway station to the return circuit by VLD-F (SCG-250-75-R01). Cited from EN 50526-3. Diverts long-tem currents of the low amplitutes Usually Combined with SPD According to the new standard EN 50526-2 Voltage Limiting Devices VLD Combined with surge protective deviceProtective Devices , whose function is to prevent existence of an impermissible high touch Voltage and to limit overvoltage in AC and also DC electric railway Limiting device VLD class - type range BVLBVL incorporates by two antiparallel-connected high-performance thyristors and electronic detection circuit (EDC) together forming the Voltage Limiting device (VLD) and the parallel varistor surge pro-tection device (SPD), which are connected between two main ter-minals.
Voltage Limiting Devices Combined with SPD For electric railway system 09 / 2016
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Overvoltage, Lightning, Induced, THE LIGHTNING PROTECTION INTERNATIONAL, THE LIGHTNING PROTECTION INTERNATIONAL STANDARD, LIGHTNING PROTECTION OF OVERHEAD POWER, LIGHTNING PROTECTION OF OVERHEAD POWER DISTRIBUTION, Standard EN 50160 Voltage Characteristics, Standard EN 50160 Voltage Characteristics in Public Distribution, BOXES Cross bonding and sectionalisation for, Eaton, S guide to surge suppression