3-Phase Induction Motors - UNLV
• Motor Slip • R 1 and R 2: stator and rotor winding resistances • X 1 and X 2: stator and rotor winding leakage reactances • X m: magnetizing reactance • R c: core loss resistance • Rotor winding parameters are referred to the stator side s s m n n n s Power flow diagram 3 [ (1 ) / ] 3 3 ( / ) 3 / 3 …
Download 3-Phase Induction Motors - UNLV
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Power Semiconductor Switching Devices
www.egr.unlv.eduClassification of power semiconductor switches ... • The MCT is a power switch with a MOS gate for turn- on and turn-off. It
Power Semiconductor Switching Devices - …
www.egr.unlv.eduIdeal controllable Power Semiconductor Switch • When turned on, current can flow only in the direction of the arrow
EE 340 Spring 2011 - Howard R. Hughes College of …
www.egr.unlv.eduConstruction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field.
EE 340 – Transmission Lines
www.egr.unlv.eduElectrical Characteristics • Transmission lines are characterized by a series resistance, inductance, and shunt capacitance per unit length. • These values determine the power-carrying capacity of the
Mechanics of Materials - University of Nevada, Las Vegas
www.egr.unlv.eduME 302 Materials Mechanics Introduction and Overview This is a fundamental course in all Civil and Mechanical Engineering Programs. Sometimes it is called:
Material, Mechanics, Mechanics of materials, Materials mechanics
Resonant Converters - University of Nevada, Las Vegas
www.egr.unlv.edu9-12 ZCS Resonant-Switch Converter By controlling the switch-off time (t 4 - t 3), i.e., the switching frequency, the average value of v oi, hence the average power supplied to the load
PowerPoint Presentation
www.egr.unlv.eduThe Laplace Transform Theorem: Initial Value If the function f(t) and its first derivative are Laplace transformable and f(t) Has the Laplace transform F(s), and the exists, then
Sunlight and its Properties - Howard R. Hughes College of ...
www.egr.unlv.eduTypes of Radiations • Scattered sunlight (what makes the sky blue) is responsible for the light entering the north-facing windows. It is referred to as diffuse radiation.
Magnetic Circuits - UNLV
www.egr.unlv.eduAmpère in 1826) relates the integrated magnetic field around a closed loop to the electric current passing through the loop. where H is the magnetic field intensity (measured in At/m) • At a distance r from the wire, ³ H .dl I ³ H .dl H .( 2Sr ) I
Obtain the z parameters for the network in Fig. 19.65.
www.egr.unlv.edu* Find the impedance parameter equivalent of the network in Fig. 19.66. Figure 19.66 For Prob. 19.2. * An asterisk indicates a challenging problem. Chapter 19, Solution 2. Consider the circuit in Fig. (a) to get z11 and z21. 1 Ω I2 = 0 + V1 − 1 Ω I1 (a) Io + V2 − Io' 1 Ω 1 Ω 1 Ω 1 Ω 1 Ω 1 Ω
Related documents
EE 340 Spring 2011 - UNLV
www.egr.unlv.eduSlip rings are metal rings completely encircling the shaft of a machine but insulated from it. Graphite-like carbon brushes connected to DC terminals ... 3. The armature resistance. Open circuit Test Since the unsaturated core of the machine has a reluctance thousands times lower than the …
A Textbook of Electrical Technology Vol. 2 - Theraja - Weebly
www.kurratul.weebly.comMethods of Improving Commutation—Resistance Commuta- or Compoles— Qualising Connections—parallel Operation of Shunt Genera- tors—ParallelingD -C. Generator—Load Sharing—Procedure for paralleling D _C_ Generators— Compound Generators in Parallel—Series Generators in Parallel. 966 25. Elements of Electro-mechanical Energy …
Instruction Manual & Exercise Guide
images-na.ssl-images-amazon.comSlip one end of the band through the loop portion of the door anchor piece. STEP 3 ... 3. 4. Stand on the middle of a resistance tube with one handle in each hand near your shoulders, palms facing forward. Bend both arms at a 90-degree angle with elbows aligned with shoulders.
3 4 5 6 7 8 9 10 11 12 13 14 15 - SDP/SI
sdp-si.comi r 1 2 3 4 5 6 7 8 9 10 11 12 13 t 14 15 a phone: 516.328.3300 • fax: 516.326.8827 • www.sdp-si.com timing belts, pulleys, chains and sprockets table of contents ...
LADDER SAFETY - University of Washington
www.ehs.washington.edufiberglass ladders, which must be able to sustain 3.3 times the maximum intended load. Fixed ladders cannot be readily moved or carried because they are an integral part of a building or structure. Never subject a ladder to a load greater than its duty rating, which is the total load of the person’s weight, equipment, tools and materials.
AC Motor Speed Control - University of Alabama
www.me.ua.eduVariable Series Resistance ... Variable Resistor “The traditional way to control the speed of a wound rotor induction motor is to increase the slip by adding resistance in the rotor circuit. ...
Control, Resistance, Motor, Speed, Slip, Ac motor speed control