CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
3003.3.2.2 More than three elevators. Where a floor is serviced by more than three elevator cars, at least three elevator cars with a total rated load capacity of not less
System, Elevator, Less, Conveying, 30 elevators and conveying systems
Download CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
CHAPTER 16 STRUCTURAL DESIGN - iccsafe.org
www2.iccsafe.orgCHAPTER 16 STRUCTURAL DESIGN SECTION 1601 GENERAL 1601.1 Scope. The provisions of this chapter shall govern the structural design of …
CHAPTER 10 MEANS OF EGRESS - iccsafe.org
www2.iccsafe.orgINTERNATIONAL BUILDING CODE 2006, ... means of egress of a building or portion thereof is ... 196 INTERNATIONAL BUILDING CODE 2006, NEW JERSEY EDITION MEANS OF EGRESS
International, Name, Code, Building, Iccsafe, International building code, Means of egress, Egress
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
www2.iccsafe.org16 international building code 2006, new jersey edition use and occupancy classification 03_nj_bldg_2006.prn 2
CHAPTER 7 SANITARY DRAINAGE - iccsafe.org
www2.iccsafe.orgSECTION 703 BUILDING SEWER 703.1 Buildingsewerpipenearthewaterservice.Wherethe buildingsewerisinstalledwithin5feet(1524mm)of thewater service, the installation shall comply with the provisions of
Section, Chapter, Building, Iccsafe, Sewer, Sanitary, Drainage, Chapter 7 sanitary drainage, Building sewer
CHAPTER 3 USE AND OCCUPANCY …
www2.iccsafe.orgCHAPTER 3 USE AND OCCUPANCY CLASSIFICATION SECTION 301 GENERAL 301.1 Scope. The provisions of this chapter shall control the classificationof allbuildings and structures astouseand occu-
Classification, Occupancy, Use and occupancy, Use and occupancy classification
CHAPTER 17 STRUCTURAL TESTS AND SPECIAL …
www2.iccsafe.orgCHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONS SECTION 1701 GENERAL 1701.1 Scope. The provisions of this chapter shall apply to Class I buildings and shall govern the quality, workmanship
Tests, Special, Structural, Inspection, Structural tests and special, Structural tests and special inspections
CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
www2.iccsafe.orgCHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION BC 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials and assemblies used for structural fire resistance and
CHAPTER 16 STRUCTURAL DESIGN - iccsafe.org
www2.iccsafe.orgCHAPTER 16 STRUCTURAL DESIGN SECTION BC 1601 GENERAL 1601.1 Scope. The provisions of this chapter shall govern the structural design …
Design, Chapter, Structural, Iccsafe, Chapter 16 structural design
CHAPTER 16 STRUCTURAL LOADS - iccsafe.org
www2.iccsafe.orgCHAPTER 16 STRUCTURAL LOADS SECTION 1601 GENERAL 1601.1 Scope. Provisions of this chapter shall govern the structural design of …
Chapter, Structural, Load, Iccsafe, Chapter 16 structural loads iccsafe, Chapter 16 structural loads
CHAPTER 7 FIRE-RESISTANCE-RATED …
www2.iccsafe.orgCHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials and assemblies used for structural fire resistance and
Resistance, Construction, Trade, Fire, Fire resistance rated, Fire resistance rated construction
Related documents
State of Ohio Elevator Inspection Section - Kentucky
dhbc.ky.gov____ - ACCESS/ROOF-HOISTWAY---Access to and from the roof and machine room shall be by the means of a stairway. When access is over a sloping roof or a roof with vertical obstructions, a walkway shall be provided.
States, Section, Machine, Inspection, Room, Ohio, Elevator, State of ohio elevator inspection section, Machine room
KONE Accessibility Pack – EN81-70
www.euroliftgroup.comThe leading machine-room-less elevator Durable, functional, reli-able Optimum user comfort Attractive visual design Space-saving features
Machine, Room, Pack, Less, Accessibility, Oken, Kone accessibility pack en81 70, En81
Vertical Transportation in Tall Buildings Dr Gina Barney ...
www.highrisefirefighting.co.ukVertical transportation Page 1 of 12 pages Vertical Transportation in Tall Buildings Dr Gina Barney, natcon.pap Gina Barney Associates, PO Box 7, Sedbergh, LA10 5GE.
Associate, Gain, Bayern, Gina barney associates, Dr gina barney
Reference Standard 18 REFERENCE STANDARD RS-18 …
www.nyc.govReference Standard 18 343 REFERENCE STANDARD RS-18 ELEVATORS AND CONVEYORS *LIST OF REFERENCED NATIONAL STANDARDS ANSI/ASME A17.1Safety Code for Elevators and Escalators and Supplements A17.1a-1997 as Modified…..1996
Reference Standard 9 REFERENCE STANDARD RS 9 LOADS …
www.nyc.govReference Standard 9 106 CONCENTRATED LIVE LOADS. Use or Location Load (lbs.) a. Remarks Elevator machine room floor See Reference Standard RS 18 Gratings, checkered plates
Standards, Machine, Reference, Room, Reference standard, Machine room
New Equipment - Peelle Doors
www.peelledoor.comNEW EQUIPMENT www.peelledoor.com GUIDE 306 PEELLE FREIGHT ELEVATOR DOORS 2 ® Door Types – ISO Class IV The two Peelle door types are biparting (counterbalanced) and slide-up (counterweighted), both of which slide vertically.