Dedicated Outdoor Air Systems - Greenheck-USA
Dedicated Outdoor Air Systems for high percentage and 100% outside air Models RV and RVE • Institutional • Commercial • Industrial • Up to 18,000 cfm • 3 in. wg External Static Pressure • Packaged DX (3-70 tons), Chilled Water, Split DX Cooling with or without Remote Condenser, Air-Source Heat Pump (5-30 tons)
Download Dedicated Outdoor Air Systems - Greenheck-USA
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Minimum 180 in-lb Torque Applications
content.greenheck.comFor damper areas up to 45 sq-ft*(For lower torque, see AF, NFB, LF, ... Time to fit your Specific Application with Belimo’s Flexible Line of ... done in accordance with the damper manufacturer’s specifications. Control is On/Off from an auxiliary contact, or a manual switch. ...
Modular Make-Up Air Unit - content.greenheck.com
content.greenheck.comModular Make-Up Air Unit Model MSX Commercial, Industrial, and Kitchen Applications ... supply air for general, process and combustion exhaust. ... • Airflow Arrangement - Optional Variable Air Volume or Constant Volume 100% Outdoor Air • Performance Range - 800 to 7,500 cfm ...
Heating and Ventilating Units - content.greenheck.com
content.greenheck.com2 Heating Options Hot water, steam and electric heat options are available. The heating section consists of a factory-installed heating coil in a pre-engineered housing.
Energy Recovery and Make-Up Air Start-Up Report
content.greenheck.com5 Condenser Airflow S 6 6 4 8 5 3 4 12 4 1 2 14 13 11 10 9 Supply Airflow P1 P2 T1 T2 Packaged DX Cooling with Digital Scroll Compressor Water-Source Heat Pump with Standard Scroll Compressor
Indirect Gas-Fired Make-Up Air - content.greenheck.com
content.greenheck.com5 Controls Discharge Temperature Control In make-up air units, the unit-controlled heat output is based on discharge temperature. A factory-mounted
High Performance Vane Axial Fans - content.greenheck.com
content.greenheck.comfi 2 Model RA High Performance Vane Axial Fans RA high performance, direct-driven vane axial fans are ideal for inline air ventilation in commercial, institutional or industrial buildings.
Centrifugal Ceiling Exhaust and Inline Cabinet Fans
content.greenheck.com3 Model Comparison Model Location Mounting Airflow Application Drive Type Impeller Type Performance Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted Exhaust Supply Reversible Recirculate General/Clean Air Contaminated Air Spark Resistant Grease (UL 762) Smoke Control (UL) High Wind (150 mph) High Temp (above 200°F ) Belt Direct Centrifugal Propeller/Axial …
Installation, Operation and Maintenance Manual
content.greenheck.com2 Ceiling Exhaust and Inline Fans ® Typical Installation The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of
FumeJet Exhaust Systems - content.greenheck.com
content.greenheck.com2 Greenheck’s FumeJet® line of exhaust fans with integral stacks are designed to safely remove and disperse fumes and odors. FumeJet systems replace utility set fans with field supplied intake
Installation, Operation and Maintenance Manual
content.greenheck.comUpblast Centrifugal Roof Exhaust 3 ® When lifting a Belt Drive unit onto the roof, use either the four lifting points on the drive frame or the two lifting
Related documents
HVAC Control & Balancing Dampers - Greenheck-USA
content.greenheck.comCommercial Control Dampers are used in buildings to regulate the flow of air in an HVAC system. They can be used in intake, exhaust, or mixed air applications. There are two categories of control ... Air leakage is based on operation between 32° and 120°F (0 and 49°C).
2019 Energy Code Nonresidential Envelope
www.energy.ca.govAll Buildings § 10-101 to § 10-115. Regulations, definitions, permitting, compliance, enforcement, acceptance testing providers, local ordinances, interpretations, certification, labeling for fenestration and roofs, outdoor lighting zones, community shared solar, and battery storage. Relevant sections § 10-111 – Fenestration and door labels
8. Air Distribution Systems - Energy Star
www.energystar.govConsider a Testing, Adjusting, and Balancing Contractor 26 ... the fans that move conditioned air through commercial office buildings account for about 7 percent of the total energy consumed by these buildings ... posed to be fully closed. During cooling operation, warm duct leakage increases the energy necessary to condition the space. The ...
System, Testing, Distribution, Commercial, Building, Energy, Star, Leakage, Energy star, Air distribution systems
Air-Cooled Liquid Chillers - Trane
www.trane.comThe 10 and 15-ton air-cooled Cold Generator™ chillers, with Trane direct drive hermetic scroll compressors, has outstanding standard features and additional benefits that make selection, installation, and servicing easy. Flexibility Footprint Central to the design of any project is the operating envelope of the air-cooled packaged chiller.
Packaged Rooftop Air Conditioners - Trane
www.trane.comProven Design Through Testing and Research With over twenty years of development and testing, Trane 3-D Scroll compressors have undergone more than 400,000 hours of laboratory testing and field operation. This work combined with over 25 patents makes Trane the worldwide leader in air conditioning scroll compressor technology. Features and Benefits
2020 NYCECC - How-to Guide: Supporting Documentation ...
www1.nyc.govdemarcation line must be indicated on building elevation drawings for Commercial buildings. ... demonstrate that the air leakage of fenestration assemblies do not exceed the maximum allowed leakage rate. ... Drawings must specify mandatory air barrier testing/inspection requirements specific to the building type.
Testing, Commercial, Building, Leakage, Commercial buildings, Air leakage